We assessed total body water (TBW) and extracellular water (ECW) in thirty-four non-ascitic cirrhotics and twenty healthy controls by (H2O)-H-2 and Br dilution, In the same subjects, bioelectric impedance (BI) was recorded at multiple frequencies, Body hydration was similar for controls (mean 55.6 (SD 6.7)), less-severe cirrhotics (Child-Pugh classification A; CPA; n 21, mean 56.2 (SD 6.2)) and moderately-severe cirrhotics (Child-Pugh classification B; CPB; n 13, mean 57.2 (SD 5.4)), However, intracellular water standardized per litre TBW was significantly higher in CPB subjects (mean 27.0 (SD 7.5); P < 0.01) compared with CPA (mean 21.3 (SD 10.6)) and control subjects (mean 18.0 (SD 9.8)), Published formulas for predicting TBW and ECW from BI at multiple frequencies were applied to the cirrhotics, These formulas gave accurate predictions of TBW and ECW, although standard errors of estimates were higher for CPB subjects (TBW less than or equal to 2.5 and ECW less than or equal to 2.11) than those for CPA (TBW less than or equal to 2.0 and ECW less than or equal to 1.81) and control (TBW 1.4 and ECW 0.91) subjects.

Borghi, A., Bedogni, G., Rocchi, E., Severi, S., Farina, F., Battistini, N. (1996). Multi-frequency bioelectric impedance measurements for predicting body water compartments in patients with non-ascitic liver cirrhosis. BRITISH JOURNAL OF NUTRITION, 76(3), 325-332 [10.1079/BJN19960039].

Multi-frequency bioelectric impedance measurements for predicting body water compartments in patients with non-ascitic liver cirrhosis

Bedogni, G
Secondo
;
1996

Abstract

We assessed total body water (TBW) and extracellular water (ECW) in thirty-four non-ascitic cirrhotics and twenty healthy controls by (H2O)-H-2 and Br dilution, In the same subjects, bioelectric impedance (BI) was recorded at multiple frequencies, Body hydration was similar for controls (mean 55.6 (SD 6.7)), less-severe cirrhotics (Child-Pugh classification A; CPA; n 21, mean 56.2 (SD 6.2)) and moderately-severe cirrhotics (Child-Pugh classification B; CPB; n 13, mean 57.2 (SD 5.4)), However, intracellular water standardized per litre TBW was significantly higher in CPB subjects (mean 27.0 (SD 7.5); P < 0.01) compared with CPA (mean 21.3 (SD 10.6)) and control subjects (mean 18.0 (SD 9.8)), Published formulas for predicting TBW and ECW from BI at multiple frequencies were applied to the cirrhotics, These formulas gave accurate predictions of TBW and ECW, although standard errors of estimates were higher for CPB subjects (TBW less than or equal to 2.5 and ECW less than or equal to 2.11) than those for CPA (TBW less than or equal to 2.0 and ECW less than or equal to 1.81) and control (TBW 1.4 and ECW 0.91) subjects.
1996
Borghi, A., Bedogni, G., Rocchi, E., Severi, S., Farina, F., Battistini, N. (1996). Multi-frequency bioelectric impedance measurements for predicting body water compartments in patients with non-ascitic liver cirrhosis. BRITISH JOURNAL OF NUTRITION, 76(3), 325-332 [10.1079/BJN19960039].
Borghi, A; Bedogni, G; Rocchi, E; Severi, S; Farina, F; Battistini, N
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/959955
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 12
social impact