Background: Selective clamping during robot-assisted partial nephrectomy (RAPN) requires extensive knowledge on patient-specific renal vasculature, obtained through imaging.Objective: To validate an in-house developed perfusion zone algorithm that provides patient-specific three-dimensional (3D) renal perfusion information.Design, setting, and participants: Between October 2020 and June 2022, 25 patients undergoing RAPN at Ghent University Hospital were included. Three-dimensional mod-els, based on preoperative computed tomography (CT) scans, showed the clamped artery's ischemic zone, as calculated by the algorithm.Surgical procedure: All patients underwent selective clamping during RAPN. Indocyanine green (ICG) was administered to visualize the true ischemic zone perioperatively. Surgery was recorded for a postoperative analysis.Measurements: The true ischemic zone of the clamped artery was compared with the ischemic zone predicted by the algorithm through two metrics: (1) total ischemic zone overlap and (2) tumor ischemic zone overlap. Six urologists assessed metric 1; metric 2 was assessed objectively by the authors.Results and limitations: In 92% of the cases, the algorithm was sufficiently accurate to plan a selective clamping strategy. Metric 1 showed an average score of 4.28 out of 5. Metric 2 showed an average score of 4.14 out of 5. A first limitation is that ICG can be evaluated only at the kidney surface. A second limitation is that mainly patients with impaired renal function are expected to benefit from this technology, but contrast -enhanced CT is required at present.Conclusions: The proposed new tool demonstrated high accuracy when planning selec-tive clamping for RAPN. A follow-up prospective study is needed to determine the tool's clinical added value.Patient summary: In partial nephrectomy, the surgeon has no information on which specific arterial branches perfuse the kidney tumor. We developed a surgeon support system that visualizes the perfusion zones of all arteries on a three-dimensional model and indicates the correct arteries to clamp. In this study, we validate this tool.(c) 2023 European Association of Urology. Published by Elsevier B.V. All rights reserved.
De Backer, P., Vermijs, S., Van Praet, C., De Visschere, P., Vandenbulcke, S., Mottaran, A., et al. (2023). A Novel Three-dimensional Planning Tool for Selective Clamping During Partial Nephrectomy: Validation of a Perfusion Zone Algorithm. EUROPEAN UROLOGY, 83(5), 413-421 [10.1016/j.eururo.2023.01.003].
A Novel Three-dimensional Planning Tool for Selective Clamping During Partial Nephrectomy: Validation of a Perfusion Zone Algorithm
Mottaran, Angelo;
2023
Abstract
Background: Selective clamping during robot-assisted partial nephrectomy (RAPN) requires extensive knowledge on patient-specific renal vasculature, obtained through imaging.Objective: To validate an in-house developed perfusion zone algorithm that provides patient-specific three-dimensional (3D) renal perfusion information.Design, setting, and participants: Between October 2020 and June 2022, 25 patients undergoing RAPN at Ghent University Hospital were included. Three-dimensional mod-els, based on preoperative computed tomography (CT) scans, showed the clamped artery's ischemic zone, as calculated by the algorithm.Surgical procedure: All patients underwent selective clamping during RAPN. Indocyanine green (ICG) was administered to visualize the true ischemic zone perioperatively. Surgery was recorded for a postoperative analysis.Measurements: The true ischemic zone of the clamped artery was compared with the ischemic zone predicted by the algorithm through two metrics: (1) total ischemic zone overlap and (2) tumor ischemic zone overlap. Six urologists assessed metric 1; metric 2 was assessed objectively by the authors.Results and limitations: In 92% of the cases, the algorithm was sufficiently accurate to plan a selective clamping strategy. Metric 1 showed an average score of 4.28 out of 5. Metric 2 showed an average score of 4.14 out of 5. A first limitation is that ICG can be evaluated only at the kidney surface. A second limitation is that mainly patients with impaired renal function are expected to benefit from this technology, but contrast -enhanced CT is required at present.Conclusions: The proposed new tool demonstrated high accuracy when planning selec-tive clamping for RAPN. A follow-up prospective study is needed to determine the tool's clinical added value.Patient summary: In partial nephrectomy, the surgeon has no information on which specific arterial branches perfuse the kidney tumor. We developed a surgeon support system that visualizes the perfusion zones of all arteries on a three-dimensional model and indicates the correct arteries to clamp. In this study, we validate this tool.(c) 2023 European Association of Urology. Published by Elsevier B.V. All rights reserved.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.