PLATO (Planetary Transits and Oscillations of stars) is a new space telescope selected by ESA to detect terrestrial exoplanets in nearby solar-type stars. The telescope is composed by 26 small telescopes to achieve a large instantaneous field of view. INAF-OAPD is directly involved in the optical design and in the definition and testing of the alignment strategy. A prototype of the Telescope Optical Unis (TOU) was assembled and integrated in warm condition (room temperature) and then the performance is tested in warm and cold temperature (-80C). The mechanical structure of the TOU is representative in terms of thermal expansion coefficient and Young's modulus with respect to the actual one. A dedicated GSE (Ground Support Equipment) is used to manipulate the lenses. By co-align an interferometer and a laser with respect to the center of the third CaF2 lens, a several observables references are used to define the position and tilt of the chief ray. The total procedure tolerances for every lens is 30'' in tilt, between 15-40 μm for focus and 22 μm for decentering and the total error budget of the optical setup bench is below this requirement. In this paper, we describe the AIV procedure and test performed on the prototype of the TOU in the INAF laboratory.

G. Umbriaco, F. Biondi, J. Farinato, V. Viotto, L. Marafatto, M. Bergomi, et al. (2018). The telescope optical units prototype and AIV in the framework of the PLATO ESA mission.

The telescope optical units prototype and AIV in the framework of the PLATO ESA mission

G. Umbriaco;
2018

Abstract

PLATO (Planetary Transits and Oscillations of stars) is a new space telescope selected by ESA to detect terrestrial exoplanets in nearby solar-type stars. The telescope is composed by 26 small telescopes to achieve a large instantaneous field of view. INAF-OAPD is directly involved in the optical design and in the definition and testing of the alignment strategy. A prototype of the Telescope Optical Unis (TOU) was assembled and integrated in warm condition (room temperature) and then the performance is tested in warm and cold temperature (-80C). The mechanical structure of the TOU is representative in terms of thermal expansion coefficient and Young's modulus with respect to the actual one. A dedicated GSE (Ground Support Equipment) is used to manipulate the lenses. By co-align an interferometer and a laser with respect to the center of the third CaF2 lens, a several observables references are used to define the position and tilt of the chief ray. The total procedure tolerances for every lens is 30'' in tilt, between 15-40 μm for focus and 22 μm for decentering and the total error budget of the optical setup bench is below this requirement. In this paper, we describe the AIV procedure and test performed on the prototype of the TOU in the INAF laboratory.
2018
Space Telescopes and Instrumentation 2018: Optical, Infrared, and Millimeter Wave
1
13
G. Umbriaco, F. Biondi, J. Farinato, V. Viotto, L. Marafatto, M. Bergomi, et al. (2018). The telescope optical units prototype and AIV in the framework of the PLATO ESA mission.
G. Umbriaco; F. Biondi; J. Farinato; V. Viotto; L. Marafatto; M. Bergomi; E. Portaluri; E. Carolo; D. Greggio; R. Ragazzoni; D. Magrin; S. Chinellato;...espandi
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/958630
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact