A numerical study was performed in the present work about an Overtopping Device Wave Energy Converter (OTD-WEC) with one and two ramps incorporated in a real breakwater. The Constructal Design method was applied to evaluate the effects on the average dimensionless overtopping flow of the degrees of freedom of the device with one and two ramps. In addition, a comparison was carried out among the different geometry configurations of the OTD-WEC to determine which one presents the best hydrodynamic performance. The work used the JONSWAP spectrum and the multiphase Volume of Fluid model. It also solved the conservation equations for mass, momentum, and an equation for the transport of the volume fraction using the Finite Volume Method. Results showed that a device with a two-ramps configuration presented an average dimensionless overtopping flow 6.48% higher than those obtained for the one ramp. Present results obtained using Constructal Design theoretical recommendations about the influence of a complex configuration with four degrees of freedom over the performance of an OTD-WEC integrated into the east breakwater of the city of São José do Norte, State of Rio Grande do Sul (RS), Brazil.

Constructal Design of an Overtopping Wave Energy Converter Incorporated in a Breakwater / Martins J.C.; Fragassa C.; Goulart M.M.; Dos Santos E.D.; Isoldi L.A.; Gomes M.D.N.; Rocha L.A.O.. - In: JOURNAL OF MARINE SCIENCE AND ENGINEERING. - ISSN 2077-1312. - STAMPA. - 10:4(2022), pp. 471.1-471.28. [10.3390/jmse10040471]

Constructal Design of an Overtopping Wave Energy Converter Incorporated in a Breakwater

Fragassa C.
;
2022

Abstract

A numerical study was performed in the present work about an Overtopping Device Wave Energy Converter (OTD-WEC) with one and two ramps incorporated in a real breakwater. The Constructal Design method was applied to evaluate the effects on the average dimensionless overtopping flow of the degrees of freedom of the device with one and two ramps. In addition, a comparison was carried out among the different geometry configurations of the OTD-WEC to determine which one presents the best hydrodynamic performance. The work used the JONSWAP spectrum and the multiphase Volume of Fluid model. It also solved the conservation equations for mass, momentum, and an equation for the transport of the volume fraction using the Finite Volume Method. Results showed that a device with a two-ramps configuration presented an average dimensionless overtopping flow 6.48% higher than those obtained for the one ramp. Present results obtained using Constructal Design theoretical recommendations about the influence of a complex configuration with four degrees of freedom over the performance of an OTD-WEC integrated into the east breakwater of the city of São José do Norte, State of Rio Grande do Sul (RS), Brazil.
2022
Constructal Design of an Overtopping Wave Energy Converter Incorporated in a Breakwater / Martins J.C.; Fragassa C.; Goulart M.M.; Dos Santos E.D.; Isoldi L.A.; Gomes M.D.N.; Rocha L.A.O.. - In: JOURNAL OF MARINE SCIENCE AND ENGINEERING. - ISSN 2077-1312. - STAMPA. - 10:4(2022), pp. 471.1-471.28. [10.3390/jmse10040471]
Martins J.C.; Fragassa C.; Goulart M.M.; Dos Santos E.D.; Isoldi L.A.; Gomes M.D.N.; Rocha L.A.O.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/958440
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 6
social impact