Objective: We compared the outcomes of patients treated with nonbare stents (NBS) and proximal bare stents (PBS) endografts with a proximal landing zone in the aortic arch during thoracic endovascular aortic repair (TEVAR). Methods: We conducted a retrospective cohort, observational, multicenter study that included 361 consecutive TEVAR procedures undertaken between November 2005 and December 2021. TEVAR patients with both BS and NBS Relay stent graft configurations with proximal landing in zones 1, 2, or 3 were enrolled. Preoperative anamnestic and morphological data, clinical outcomes, and aortic modifications 30 days after surgery and at the latest follow-up available were collected. The primary outcome was freedom from proximal endoleak (type IA) comparing the two configurations. Total and detailed endoleak rates, clinical and technical success, intraoperative additional maneuvers, major adverse events, and reinterventions were secondary outcomes. Results: The median follow-up was 4.9 (interquartile range, 2.0-8.1) years. No statistically significant difference between NBS and PBS patients concerning 30-day major adverse events, retrograde aortic dissection, disabling stroke, or late type IA endoleak (10.8% vs 7.8%; P = .597). Aneurysmal disease (P = .026), PLZ diameter of >34 mm (P = .026), aortic tortuosity index of >1.4 (P = .008), type III aortic arch (P = .068), and PLZ thrombus (P = .014) identified as risk factors by univariate Cox regression analysis. PLZ thrombus was the only type IA endoleak risk factor at multivariate Cox regression (P = .016). Conclusions: We found no statistically significant difference in freedom from type IA endoleak, retrograde dissection, or disabling stroke observed between the NBS and the BS configuration of the Relay endograft. Proximal landing zone thrombotic apposition was a prominent risk factor for type IA endoleak after TEVAR.

Leone N., Bartolotti L.A.M., Capitain A.N., Migliari M., Silingardi R., Czerny M., et al. (2024). Comparison of bare and nonbare stent grafts during thoracic endovascular aneurysm repair of the aortic arch. JOURNAL OF VASCULAR SURGERY, 79(5), 997-1004 [10.1016/j.jvs.2023.12.034].

Comparison of bare and nonbare stent grafts during thoracic endovascular aneurysm repair of the aortic arch

Leone N.
Primo
Project Administration
;
Bartolotti L. A. M.;Migliari M.;
2024

Abstract

Objective: We compared the outcomes of patients treated with nonbare stents (NBS) and proximal bare stents (PBS) endografts with a proximal landing zone in the aortic arch during thoracic endovascular aortic repair (TEVAR). Methods: We conducted a retrospective cohort, observational, multicenter study that included 361 consecutive TEVAR procedures undertaken between November 2005 and December 2021. TEVAR patients with both BS and NBS Relay stent graft configurations with proximal landing in zones 1, 2, or 3 were enrolled. Preoperative anamnestic and morphological data, clinical outcomes, and aortic modifications 30 days after surgery and at the latest follow-up available were collected. The primary outcome was freedom from proximal endoleak (type IA) comparing the two configurations. Total and detailed endoleak rates, clinical and technical success, intraoperative additional maneuvers, major adverse events, and reinterventions were secondary outcomes. Results: The median follow-up was 4.9 (interquartile range, 2.0-8.1) years. No statistically significant difference between NBS and PBS patients concerning 30-day major adverse events, retrograde aortic dissection, disabling stroke, or late type IA endoleak (10.8% vs 7.8%; P = .597). Aneurysmal disease (P = .026), PLZ diameter of >34 mm (P = .026), aortic tortuosity index of >1.4 (P = .008), type III aortic arch (P = .068), and PLZ thrombus (P = .014) identified as risk factors by univariate Cox regression analysis. PLZ thrombus was the only type IA endoleak risk factor at multivariate Cox regression (P = .016). Conclusions: We found no statistically significant difference in freedom from type IA endoleak, retrograde dissection, or disabling stroke observed between the NBS and the BS configuration of the Relay endograft. Proximal landing zone thrombotic apposition was a prominent risk factor for type IA endoleak after TEVAR.
2024
Leone N., Bartolotti L.A.M., Capitain A.N., Migliari M., Silingardi R., Czerny M., et al. (2024). Comparison of bare and nonbare stent grafts during thoracic endovascular aneurysm repair of the aortic arch. JOURNAL OF VASCULAR SURGERY, 79(5), 997-1004 [10.1016/j.jvs.2023.12.034].
Leone N.; Bartolotti L.A.M.; Capitain A.N.; Migliari M.; Silingardi R.; Czerny M.; Rylski B.; Gennai S.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/957745
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact