The mechanism of the electrocatalytic oxidation towards a wide series of alcohols, by an electrode covered with the [Ni/Al-Cl] hydrotalcyte-like clay, has been analyzed in the different steps it consists of. Such a clay has been reported to be electrically conductive via a mechanism that shows similarities with that of the redox polymers. The overall process occurs in quite a complicated physical system that is completely different both from a classical electrode-solution one and from an electrode covered with a film of heterogeneous catalyst. By varying the characteristics of the substrate, in terms of steric hindrance and dipole moment of the molecule, the factors affecting the redox mediator-substrate reaction have been studied. The concentration ranges where the amperometric response varies linearly have been determined for the different substrates considered.

Anionic clay modified electrode for detection of alcohols. An electrocatalytic amperometric sensor / Ballarin B.; Seeber R.; Tonelli D.; Zanardi C.. - In: ELECTROANALYSIS. - ISSN 1040-0397. - STAMPA. - 12:6(2000), pp. 434-441. [10.1002/(SICI)1521-4109(20000401)12:6<434::AID-ELAN434>3.0.CO;2-6]

Anionic clay modified electrode for detection of alcohols. An electrocatalytic amperometric sensor

Ballarin B.;Seeber R.;Tonelli D.;
2000

Abstract

The mechanism of the electrocatalytic oxidation towards a wide series of alcohols, by an electrode covered with the [Ni/Al-Cl] hydrotalcyte-like clay, has been analyzed in the different steps it consists of. Such a clay has been reported to be electrically conductive via a mechanism that shows similarities with that of the redox polymers. The overall process occurs in quite a complicated physical system that is completely different both from a classical electrode-solution one and from an electrode covered with a film of heterogeneous catalyst. By varying the characteristics of the substrate, in terms of steric hindrance and dipole moment of the molecule, the factors affecting the redox mediator-substrate reaction have been studied. The concentration ranges where the amperometric response varies linearly have been determined for the different substrates considered.
2000
Anionic clay modified electrode for detection of alcohols. An electrocatalytic amperometric sensor / Ballarin B.; Seeber R.; Tonelli D.; Zanardi C.. - In: ELECTROANALYSIS. - ISSN 1040-0397. - STAMPA. - 12:6(2000), pp. 434-441. [10.1002/(SICI)1521-4109(20000401)12:6<434::AID-ELAN434>3.0.CO;2-6]
Ballarin B.; Seeber R.; Tonelli D.; Zanardi C.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/957253
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 31
  • ???jsp.display-item.citation.isi??? ND
social impact