Dynamic contrast-enhanced ultrasound (DCE-US) is a technique to quantify tissue perfusion based on phase-specific enhancement after the injection of microbubble contrast agents for diagnostic ultrasound. The guidelines of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) published in 2004 and updated in 2008, 2011, and 2020 focused on the use of contrast-enhanced ultrasound (CEUS), including essential technical requirements, training, investigational procedures and steps, guidance regarding image interpretation, established and recommended clinical indications, and safety considerations. However, the quantification of phase-specific enhancement patterns acquired with ultrasound contrast agents (UCAs) is not discussed here. The purpose of this EFSUMB Technical Review is to further establish a basis for the standardization of DCE-US focusing on treatment monitoring in oncology. It provides some recommendations and descriptions as to how to quantify dynamic ultrasound contrast enhancement, and technical explanations for the analysis of time-intensity curves (TICs). This update of the 2012 EFSUMB introduction to DCE-US includes clinical aspects for data collection, analysis, and interpretation that have emerged from recent studies. The current study not only aims to support future work in this research field but also to facilitate a transition to clinical routine use of DCE-US.

EFSUMB Technical Review - Update 2023: Dynamic Contrast-Enhanced Ultrasound (DCE-CEUS) for the Quantification of Tumor Perfusion / Dietrich C.F.; Correas J.-M.; Cui X.-W.; Dong Y.; Havre R.F.; Jenssen C.; Jung E.M.; Krix M.; Lim A.; Lassau N.; Piscaglia F.. - In: ULTRASCHALL IN DER MEDIZIN. - ISSN 0172-4614. - ELETTRONICO. - 45:1(2023), pp. 36-46. [10.1055/a-2157-2587]

EFSUMB Technical Review - Update 2023: Dynamic Contrast-Enhanced Ultrasound (DCE-CEUS) for the Quantification of Tumor Perfusion

Dong Y.;Piscaglia F.
2023

Abstract

Dynamic contrast-enhanced ultrasound (DCE-US) is a technique to quantify tissue perfusion based on phase-specific enhancement after the injection of microbubble contrast agents for diagnostic ultrasound. The guidelines of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) published in 2004 and updated in 2008, 2011, and 2020 focused on the use of contrast-enhanced ultrasound (CEUS), including essential technical requirements, training, investigational procedures and steps, guidance regarding image interpretation, established and recommended clinical indications, and safety considerations. However, the quantification of phase-specific enhancement patterns acquired with ultrasound contrast agents (UCAs) is not discussed here. The purpose of this EFSUMB Technical Review is to further establish a basis for the standardization of DCE-US focusing on treatment monitoring in oncology. It provides some recommendations and descriptions as to how to quantify dynamic ultrasound contrast enhancement, and technical explanations for the analysis of time-intensity curves (TICs). This update of the 2012 EFSUMB introduction to DCE-US includes clinical aspects for data collection, analysis, and interpretation that have emerged from recent studies. The current study not only aims to support future work in this research field but also to facilitate a transition to clinical routine use of DCE-US.
2023
EFSUMB Technical Review - Update 2023: Dynamic Contrast-Enhanced Ultrasound (DCE-CEUS) for the Quantification of Tumor Perfusion / Dietrich C.F.; Correas J.-M.; Cui X.-W.; Dong Y.; Havre R.F.; Jenssen C.; Jung E.M.; Krix M.; Lim A.; Lassau N.; Piscaglia F.. - In: ULTRASCHALL IN DER MEDIZIN. - ISSN 0172-4614. - ELETTRONICO. - 45:1(2023), pp. 36-46. [10.1055/a-2157-2587]
Dietrich C.F.; Correas J.-M.; Cui X.-W.; Dong Y.; Havre R.F.; Jenssen C.; Jung E.M.; Krix M.; Lim A.; Lassau N.; Piscaglia F.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/957159
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 0
social impact