The limited power-budget is known to be one of the main constraints in mm-wave radio links, especially when in-building applications are considered. In particular, outdoor-to-indoor and through-floor attenuation need to be analysed and carefully characterized at mm-waves in order to correctly approach both coverage and interference assessment issues. Surprisingly, only a few studies addressed the problem and no recommendation has been provided by standardization bodies so far for mm-wave through-floor attenuation in different building types. Therefore, a measurement campaign at 27 and 38 GHz was carried out to investigate the aforementioned issues. It is observed that in-building losses heavily depend on the building type, and that modern construction techniques make through-floor penetration almost impossible. This fact highlights the need for standard models for mm-wave through-floor propagation in different kinds of buildings.
Kodra, S., Barbiroli, M., Vitucci, E.M., Fuschini, F., Degli-Esposti, V. (2024). Mm-Wave building Penetration Losses: A Measurement Based Critical Analysis. IEEE OPEN JOURNAL OF ANTENNAS AND PROPAGATION, 2024(Early Access), 1-10 [10.1109/OJAP.2024.3355817].
Mm-Wave building Penetration Losses: A Measurement Based Critical Analysis
Kodra, S.
;Barbiroli, M.;Vitucci, E. M.;Fuschini, F.;Degli-Esposti, V.
2024
Abstract
The limited power-budget is known to be one of the main constraints in mm-wave radio links, especially when in-building applications are considered. In particular, outdoor-to-indoor and through-floor attenuation need to be analysed and carefully characterized at mm-waves in order to correctly approach both coverage and interference assessment issues. Surprisingly, only a few studies addressed the problem and no recommendation has been provided by standardization bodies so far for mm-wave through-floor attenuation in different building types. Therefore, a measurement campaign at 27 and 38 GHz was carried out to investigate the aforementioned issues. It is observed that in-building losses heavily depend on the building type, and that modern construction techniques make through-floor penetration almost impossible. This fact highlights the need for standard models for mm-wave through-floor propagation in different kinds of buildings.File | Dimensione | Formato | |
---|---|---|---|
Mm-Wave_building_Penetration_Losses_A_Measurement_Based_Critical_Analysis.pdf
accesso aperto
Tipo:
Versione (PDF) editoriale
Licenza:
Creative commons
Dimensione
449.38 kB
Formato
Adobe PDF
|
449.38 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.