The limited power-budget is known to be one of the main constraints in mm-wave radio links, especially when in-building applications are considered. In particular, outdoor-to-indoor and through-floor attenuation need to be analysed and carefully characterized at mm-waves in order to correctly approach both coverage and interference assessment issues. Surprisingly, only a few studies addressed the problem and no recommendation has been provided by standardization bodies so far for mm-wave through-floor attenuation in different building types. Therefore, a measurement campaign at 27 and 38 GHz was carried out to investigate the aforementioned issues. It is observed that in-building losses heavily depend on the building type, and that modern construction techniques make through-floor penetration almost impossible. This fact highlights the need for standard models for mm-wave through-floor propagation in different kinds of buildings.

Mm-Wave building Penetration Losses: A Measurement Based Critical Analysis / Kodra, S.; Barbiroli, M.; Vitucci, E. M.; Fuschini, F.; Degli-Esposti, V.. - In: IEEE OPEN JOURNAL OF ANTENNAS AND PROPAGATION. - ISSN 2637-6431. - ELETTRONICO. - 2024:Early Access(2024), pp. 10403959.1-10403959.10. [10.1109/OJAP.2024.3355817]

Mm-Wave building Penetration Losses: A Measurement Based Critical Analysis

Kodra, S.
;
Barbiroli, M.;Vitucci, E. M.;Fuschini, F.;Degli-Esposti, V.
2024

Abstract

The limited power-budget is known to be one of the main constraints in mm-wave radio links, especially when in-building applications are considered. In particular, outdoor-to-indoor and through-floor attenuation need to be analysed and carefully characterized at mm-waves in order to correctly approach both coverage and interference assessment issues. Surprisingly, only a few studies addressed the problem and no recommendation has been provided by standardization bodies so far for mm-wave through-floor attenuation in different building types. Therefore, a measurement campaign at 27 and 38 GHz was carried out to investigate the aforementioned issues. It is observed that in-building losses heavily depend on the building type, and that modern construction techniques make through-floor penetration almost impossible. This fact highlights the need for standard models for mm-wave through-floor propagation in different kinds of buildings.
2024
Mm-Wave building Penetration Losses: A Measurement Based Critical Analysis / Kodra, S.; Barbiroli, M.; Vitucci, E. M.; Fuschini, F.; Degli-Esposti, V.. - In: IEEE OPEN JOURNAL OF ANTENNAS AND PROPAGATION. - ISSN 2637-6431. - ELETTRONICO. - 2024:Early Access(2024), pp. 10403959.1-10403959.10. [10.1109/OJAP.2024.3355817]
Kodra, S.; Barbiroli, M.; Vitucci, E. M.; Fuschini, F.; Degli-Esposti, V.
File in questo prodotto:
File Dimensione Formato  
Mm-Wave_building_Penetration_Losses_A_Measurement_Based_Critical_Analysis.pdf

accesso aperto

Tipo: Versione (PDF) editoriale
Licenza: Creative commons
Dimensione 449.38 kB
Formato Adobe PDF
449.38 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/953562
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact