In the framework of reducing carbon dioxide emissions and energy consumption, the energy retrofit of existing buildings plays a significant role and is often supported by numerical analyses of the planned activities and expected results. This study analyses a public building (a kindergarten) located in Bialystok (Poland) and aims to determine the building’s energy performance prior to and after thermal modernization. The building was examined by employing two different software packages, Audytor OZC 7.0 Pro and Trnsys 18. The thermal efficiency improvement applied to the renovated building in Bialystok was also analyzed by virtually locating the building in Bologna (Italy). Moreover, a comfort analysis focused on the classrooms of the kindergarten was carried out employing Trnsys. As a novelty, in the analysis, particular attention is paid to ventilation losses and to the influence of envelope elements properties on the building energy demand. The results arising from analyses were compared to real consumption data for the heating season. The results obtained from the two software programs display excellent agreement, and they also match the real consumption data if the heating demand is considered, while some differences arise when the cooling demand is considered.

The Energy Retrofit Impact in Public Buildings: A Numerical Cross-Check Supported by Real Consumption Data / Ballerini V.; Lubowicka B.; Valdiserri P.; Krawczyk D.A.; Sadowska B.; Klopotowski M.; Rossi di Schio E.. - In: ENERGIES. - ISSN 1996-1073. - ELETTRONICO. - 16:23(2023), pp. 7748.1-7748.21. [10.3390/en16237748]

The Energy Retrofit Impact in Public Buildings: A Numerical Cross-Check Supported by Real Consumption Data

Ballerini V.;Valdiserri P.
;
Rossi di Schio E.
2023

Abstract

In the framework of reducing carbon dioxide emissions and energy consumption, the energy retrofit of existing buildings plays a significant role and is often supported by numerical analyses of the planned activities and expected results. This study analyses a public building (a kindergarten) located in Bialystok (Poland) and aims to determine the building’s energy performance prior to and after thermal modernization. The building was examined by employing two different software packages, Audytor OZC 7.0 Pro and Trnsys 18. The thermal efficiency improvement applied to the renovated building in Bialystok was also analyzed by virtually locating the building in Bologna (Italy). Moreover, a comfort analysis focused on the classrooms of the kindergarten was carried out employing Trnsys. As a novelty, in the analysis, particular attention is paid to ventilation losses and to the influence of envelope elements properties on the building energy demand. The results arising from analyses were compared to real consumption data for the heating season. The results obtained from the two software programs display excellent agreement, and they also match the real consumption data if the heating demand is considered, while some differences arise when the cooling demand is considered.
2023
The Energy Retrofit Impact in Public Buildings: A Numerical Cross-Check Supported by Real Consumption Data / Ballerini V.; Lubowicka B.; Valdiserri P.; Krawczyk D.A.; Sadowska B.; Klopotowski M.; Rossi di Schio E.. - In: ENERGIES. - ISSN 1996-1073. - ELETTRONICO. - 16:23(2023), pp. 7748.1-7748.21. [10.3390/en16237748]
Ballerini V.; Lubowicka B.; Valdiserri P.; Krawczyk D.A.; Sadowska B.; Klopotowski M.; Rossi di Schio E.
File in questo prodotto:
File Dimensione Formato  
energies-16-07748.pdf

accesso aperto

Tipo: Versione (PDF) editoriale
Licenza: Creative commons
Dimensione 7.85 MB
Formato Adobe PDF
7.85 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/950796
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact