A HPLC method has been developed for the simultaneous determination of seven tricyclic antidepressants (TCAs) and seven metabolites in human plasma. The analyte separation was obtained using a C8 reversed phase column and a mobile phase composed of 68% aqueous phosphate buffer at pH 3.0 and 32% ACN. The UV detector was set at 220 nm and loxapine was used as the internal standard. A careful pre-treatment procedure for plasma samples was developed, using SPE on C2 cartridges, which gives satisfactory extraction yields (480%) and good sample purification. The LOQs were always lower than 9.1 ng/mL and the LODs always lower than 3.1 ng/mL for all analytes. The method was successfully applied to plasma samples from depressed patients undergoing therapy with one or more TCA drugs. Precision data (RSD o8.1%), as well as accuracy results (recovery 480%), were satisfactory and no interference from other drugs was found. Hence the method seems to be suitable for the therapeutic drug monitoring of patients treated with TCAs under monotherapy or polypharmacy regimens.
L. Mercolini, R. Mandrioli, G. Finizio, G. Boncompagni, M.A. Raggi (2010). Simultaneous HPLC determination of fourteen tricyclic antidepressants and metabolites in human plasma. JOURNAL OF SEPARATION SCIENCE, 33(1), 23-30 [10.1002/jssc.200900493].
Simultaneous HPLC determination of fourteen tricyclic antidepressants and metabolites in human plasma
MERCOLINI, LAURA;MANDRIOLI, ROBERTO;RAGGI, MARIA AUGUSTA
2010
Abstract
A HPLC method has been developed for the simultaneous determination of seven tricyclic antidepressants (TCAs) and seven metabolites in human plasma. The analyte separation was obtained using a C8 reversed phase column and a mobile phase composed of 68% aqueous phosphate buffer at pH 3.0 and 32% ACN. The UV detector was set at 220 nm and loxapine was used as the internal standard. A careful pre-treatment procedure for plasma samples was developed, using SPE on C2 cartridges, which gives satisfactory extraction yields (480%) and good sample purification. The LOQs were always lower than 9.1 ng/mL and the LODs always lower than 3.1 ng/mL for all analytes. The method was successfully applied to plasma samples from depressed patients undergoing therapy with one or more TCA drugs. Precision data (RSD o8.1%), as well as accuracy results (recovery 480%), were satisfactory and no interference from other drugs was found. Hence the method seems to be suitable for the therapeutic drug monitoring of patients treated with TCAs under monotherapy or polypharmacy regimens.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.