Dental unit waterlines (DUWLs) represent a complex environment able to promote microbial contamination, due to functional, mechanical and practical risk factors. According to a water safety plan approach, the main goal is to preserve the health of dentists, dental staff and patients. The aim of this study is to develop a DUWLs water safety plan that is able to support correct and effective maintenance and disinfection procedures. Three different water systems serve 60 dental chairs: (i) water that comes directly from municipal water (Type A), (ii) water supplied by municipal water and water bottles (Type B) and (iii) water supplied only via water bottles (Type C). For each type, Legionella and Pseudomonas aeruginosa contamination was studied, by applying a new sampling scheme, based on separate sampling from water bottles, cup filler and handpieces. Type B DUWL is the only type of DUWL contaminated by L. pneumophila (ST 59) and L. anisa (mean contamination: 608.33 ± 253.33 cfu/L) detected in cup filler and handpieces, as well as the high presence of P. aeruginosa (44.42 ± 13.25 cfu/100 mL). Two subsequent shock treatments and resampling procedures were performed by increasing disinfectant dosage and contact time and removing some DUWL components linked to biofilm growth in DUWLs. A significant reduction of contamination was obtained for both microorganisms (Legionella spp.: −100%, p < 0.001 and P. aeruginosa: −99.86%, p = 0.006). The sampling strategy proposed allows us to identify the source of contamination and better focus on the maintenance and disinfection procedures. DUWLs represent an environment that requires a multidisciplinary approach, combining the knowledge of all DUWL components to correct procedures that are able to preserve the health of personnel and patients, as well as guaranteeing DUWLs’ safe functionality.

First water safety plan approach applied to a Dental Clinic complex: identification of new risk factors associated with Legionella and P. aeruginosa contamination, using a novel sampling, maintenance and management program / Federica Marino, Marta Mazzotta, Maria Rosaria Pascale, Carlo Derelitto, Luna Girolamini, Sandra Cristino. - In: JOURNAL OF ORAL MICROBIOLOGY. - ISSN 2000-2297. - ELETTRONICO. - 15:(2023), pp. 222347.1-222347.14. [10.1080/20002297.2023.2223477]

First water safety plan approach applied to a Dental Clinic complex: identification of new risk factors associated with Legionella and P. aeruginosa contamination, using a novel sampling, maintenance and management program

Federica Marino
Primo
;
Marta Mazzotta;Maria Rosaria Pascale;Carlo Derelitto;Luna Girolamini;Sandra Cristino
Ultimo
2023

Abstract

Dental unit waterlines (DUWLs) represent a complex environment able to promote microbial contamination, due to functional, mechanical and practical risk factors. According to a water safety plan approach, the main goal is to preserve the health of dentists, dental staff and patients. The aim of this study is to develop a DUWLs water safety plan that is able to support correct and effective maintenance and disinfection procedures. Three different water systems serve 60 dental chairs: (i) water that comes directly from municipal water (Type A), (ii) water supplied by municipal water and water bottles (Type B) and (iii) water supplied only via water bottles (Type C). For each type, Legionella and Pseudomonas aeruginosa contamination was studied, by applying a new sampling scheme, based on separate sampling from water bottles, cup filler and handpieces. Type B DUWL is the only type of DUWL contaminated by L. pneumophila (ST 59) and L. anisa (mean contamination: 608.33 ± 253.33 cfu/L) detected in cup filler and handpieces, as well as the high presence of P. aeruginosa (44.42 ± 13.25 cfu/100 mL). Two subsequent shock treatments and resampling procedures were performed by increasing disinfectant dosage and contact time and removing some DUWL components linked to biofilm growth in DUWLs. A significant reduction of contamination was obtained for both microorganisms (Legionella spp.: −100%, p < 0.001 and P. aeruginosa: −99.86%, p = 0.006). The sampling strategy proposed allows us to identify the source of contamination and better focus on the maintenance and disinfection procedures. DUWLs represent an environment that requires a multidisciplinary approach, combining the knowledge of all DUWL components to correct procedures that are able to preserve the health of personnel and patients, as well as guaranteeing DUWLs’ safe functionality.
2023
First water safety plan approach applied to a Dental Clinic complex: identification of new risk factors associated with Legionella and P. aeruginosa contamination, using a novel sampling, maintenance and management program / Federica Marino, Marta Mazzotta, Maria Rosaria Pascale, Carlo Derelitto, Luna Girolamini, Sandra Cristino. - In: JOURNAL OF ORAL MICROBIOLOGY. - ISSN 2000-2297. - ELETTRONICO. - 15:(2023), pp. 222347.1-222347.14. [10.1080/20002297.2023.2223477]
Federica Marino, Marta Mazzotta, Maria Rosaria Pascale, Carlo Derelitto, Luna Girolamini, Sandra Cristino
File in questo prodotto:
File Dimensione Formato  
First water safety plan approach applied to a Dental Clinic complex identification of new risk factors associated with Legionella and P aeruginosa.pdf

accesso aperto

Tipo: Versione (PDF) editoriale
Licenza: Creative commons
Dimensione 2.81 MB
Formato Adobe PDF
2.81 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/939926
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact