Astigmatic particle tracking velocimetry (APTV) has been developed in the last years to measure the three-dimensional displacement of tracer particles using a single-camera view. The measurement principle relies on an astigmatic optical system that provides aberrated particle images with a characteristic elliptical shape univocally related to the corresponding particle depth position. Because of the precision of this method, this concept is well established for measuring and controlling the distance between a CD/DVD and the reading head. The optical arrangement of an APTV system essentially consists of a primary stigmatic optics (e.g., a microscope, or a camera objective) and an astigmatic optics, typically a cylindrical lens placed in front of the camera sensor. This paper focuses on the uncertainty of APTV in the depth direction. First, an approximated analytical model is derived and experimentally validated. From the model, a set of three non-dimensional parameters that are the most significant in the optimization of the APTV performance are identified. Finally, the effect of different parameter settings and calibration approaches are studied systematically using numerical Monte Carlo simulations. The results allow for the derivation of general criteria to minimize the overall error in APTV measurements and provide the basis for reliable uncertainty estimation for a wide range of applications.

Optimization of astigmatic particle tracking velocimeters / Rossi M.; Kahler C.J.. - In: EXPERIMENTS IN FLUIDS. - ISSN 0723-4864. - ELETTRONICO. - 55:9(2014), pp. 1-13. [10.1007/s00348-014-1809-2]

Optimization of astigmatic particle tracking velocimeters

Rossi M.
Primo
;
2014

Abstract

Astigmatic particle tracking velocimetry (APTV) has been developed in the last years to measure the three-dimensional displacement of tracer particles using a single-camera view. The measurement principle relies on an astigmatic optical system that provides aberrated particle images with a characteristic elliptical shape univocally related to the corresponding particle depth position. Because of the precision of this method, this concept is well established for measuring and controlling the distance between a CD/DVD and the reading head. The optical arrangement of an APTV system essentially consists of a primary stigmatic optics (e.g., a microscope, or a camera objective) and an astigmatic optics, typically a cylindrical lens placed in front of the camera sensor. This paper focuses on the uncertainty of APTV in the depth direction. First, an approximated analytical model is derived and experimentally validated. From the model, a set of three non-dimensional parameters that are the most significant in the optimization of the APTV performance are identified. Finally, the effect of different parameter settings and calibration approaches are studied systematically using numerical Monte Carlo simulations. The results allow for the derivation of general criteria to minimize the overall error in APTV measurements and provide the basis for reliable uncertainty estimation for a wide range of applications.
2014
Optimization of astigmatic particle tracking velocimeters / Rossi M.; Kahler C.J.. - In: EXPERIMENTS IN FLUIDS. - ISSN 0723-4864. - ELETTRONICO. - 55:9(2014), pp. 1-13. [10.1007/s00348-014-1809-2]
Rossi M.; Kahler C.J.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/918492
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 34
  • ???jsp.display-item.citation.isi??? 37
social impact