: Percutaneous Cement Discoplasty (PCD) is a minimally invasive surgical technique to treat degenerated intervertebral discs. When the disc is severely degenerated, the vacuum observed in place of the nucleus pulposus can be filled with bone cement to restore the disc height, open the foramen space, and relieve pain. This study aimed to evaluate the foramen geometry change due to PCD, in the loaded spine. Cadaveric spines (n = 25) were tested in flexion and extension while Digital Image Correlation (DIC) measured displacements and deformations. Tests were performed on simulated pre-operative condition (nucleotomy) and after PCD. Registering DIC images and the 3D specimen geometry from CT scans, a 3D model of the specimens aligned in the experimental pose was obtained for nucleotomy and PCD. Foramen space volume was geometrically measured for both conditions. The volume of cement injected was measured to explore correlation with the change of foramen space. PCD induced a significant overall foraminal decompression in both flexion (foramen space increased by 835 ± 1289 mm3, p = 0.001) and extension (1205 ± 1106 mm3, p < 0.001), confirming that the expected improvements of PCD show also during spine motion. Furthermore, in extension when the foramen is the most challenged, the impact of PCD on the foramen correlated with the injected cement volume.

Techens, C., Bereczki, F., Montanari, S., Lazary, A., Cristofolini, L., Eltes, P.E. (2023). Assessment of foraminal decompression following discoplasty using a combination of ex vivo testing and numerical tools. SCIENTIFIC REPORTS, 13, 1-10 [10.1038/s41598-023-27552-0].

Assessment of foraminal decompression following discoplasty using a combination of ex vivo testing and numerical tools

Techens, Chloe
Primo
;
Montanari, Sara;Cristofolini, Luca
Penultimo
;
2023

Abstract

: Percutaneous Cement Discoplasty (PCD) is a minimally invasive surgical technique to treat degenerated intervertebral discs. When the disc is severely degenerated, the vacuum observed in place of the nucleus pulposus can be filled with bone cement to restore the disc height, open the foramen space, and relieve pain. This study aimed to evaluate the foramen geometry change due to PCD, in the loaded spine. Cadaveric spines (n = 25) were tested in flexion and extension while Digital Image Correlation (DIC) measured displacements and deformations. Tests were performed on simulated pre-operative condition (nucleotomy) and after PCD. Registering DIC images and the 3D specimen geometry from CT scans, a 3D model of the specimens aligned in the experimental pose was obtained for nucleotomy and PCD. Foramen space volume was geometrically measured for both conditions. The volume of cement injected was measured to explore correlation with the change of foramen space. PCD induced a significant overall foraminal decompression in both flexion (foramen space increased by 835 ± 1289 mm3, p = 0.001) and extension (1205 ± 1106 mm3, p < 0.001), confirming that the expected improvements of PCD show also during spine motion. Furthermore, in extension when the foramen is the most challenged, the impact of PCD on the foramen correlated with the injected cement volume.
2023
Techens, C., Bereczki, F., Montanari, S., Lazary, A., Cristofolini, L., Eltes, P.E. (2023). Assessment of foraminal decompression following discoplasty using a combination of ex vivo testing and numerical tools. SCIENTIFIC REPORTS, 13, 1-10 [10.1038/s41598-023-27552-0].
Techens, Chloe; Bereczki, Ferenc; Montanari, Sara; Lazary, Aron; Cristofolini, Luca; Eltes, Peter Endre
File in questo prodotto:
File Dimensione Formato  
Techens-registration_cadaver-Scientic_Reports-OPEN_ACCESS.pdf

accesso aperto

Descrizione: Editorial full paper
Tipo: Versione (PDF) editoriale
Licenza: Creative commons
Dimensione 3.94 MB
Formato Adobe PDF
3.94 MB Adobe PDF Visualizza/Apri
Suppl Info.pdf

accesso aperto

Descrizione: Supplementary Information
Tipo: Versione (PDF) editoriale
Licenza: Licenza per accesso libero gratuito
Dimensione 1.44 MB
Formato Adobe PDF
1.44 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/918054
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact