SMES technology based on MgB2 superconductor and cryogenic-free cooling can offer a viable solution to power-intensive storage in the short term. One of the main obstacles to the development of dry-cooled SMES systems is the heat load removal due to the AC loss of the superconductor during fast charging and discharging cycles at high power. Accurate knowledge of the amount and distribution of AC loss in the coil is of paramount importance for the sizing and the design of the cooling system and for assessing the possible operational limits of the technology. In this manuscript, the AC loss of a 500 kJ/200 kW multifilamentary MgB2 SMES during charge–discharge cycling at full power is numerically investigated. The methodology and assumptions of the calculation are briefly resumed, and numerical results are reported and discussed in detail. In particular, the time profile and the distribution of the dissipated power all over the coil are reported. An average dissipation of 85.5 mW/m is found all over the coil during one charge–discharge cycle at full power, with a peak of 150.1 mW/m in the turns lying at the ends of the coil.

Calculation of AC Losses in a 500 kJ/200 kW Multifilamentary MgB2 SMES Coil / Morandi, Antonio; Fabbri, Massimo; Ribani, Pier Luigi; Lo Franco, Francesco; Mandrioli, Riccardo; Melaccio, Umberto; Magrassi, Daniele; Neri, Martina; Capelluto, Alessio; Tropeano, Matteo; Gandolfi, Chiara. - In: ENERGIES. - ISSN 1996-1073. - ELETTRONICO. - 16:4(2023), pp. 1596.1-1596.21. [10.3390/en16041596]

Calculation of AC Losses in a 500 kJ/200 kW Multifilamentary MgB2 SMES Coil

Morandi, Antonio
;
Fabbri, Massimo;Ribani, Pier Luigi;Lo Franco, Francesco;Mandrioli, Riccardo;Melaccio, Umberto;
2023

Abstract

SMES technology based on MgB2 superconductor and cryogenic-free cooling can offer a viable solution to power-intensive storage in the short term. One of the main obstacles to the development of dry-cooled SMES systems is the heat load removal due to the AC loss of the superconductor during fast charging and discharging cycles at high power. Accurate knowledge of the amount and distribution of AC loss in the coil is of paramount importance for the sizing and the design of the cooling system and for assessing the possible operational limits of the technology. In this manuscript, the AC loss of a 500 kJ/200 kW multifilamentary MgB2 SMES during charge–discharge cycling at full power is numerically investigated. The methodology and assumptions of the calculation are briefly resumed, and numerical results are reported and discussed in detail. In particular, the time profile and the distribution of the dissipated power all over the coil are reported. An average dissipation of 85.5 mW/m is found all over the coil during one charge–discharge cycle at full power, with a peak of 150.1 mW/m in the turns lying at the ends of the coil.
2023
Calculation of AC Losses in a 500 kJ/200 kW Multifilamentary MgB2 SMES Coil / Morandi, Antonio; Fabbri, Massimo; Ribani, Pier Luigi; Lo Franco, Francesco; Mandrioli, Riccardo; Melaccio, Umberto; Magrassi, Daniele; Neri, Martina; Capelluto, Alessio; Tropeano, Matteo; Gandolfi, Chiara. - In: ENERGIES. - ISSN 1996-1073. - ELETTRONICO. - 16:4(2023), pp. 1596.1-1596.21. [10.3390/en16041596]
Morandi, Antonio; Fabbri, Massimo; Ribani, Pier Luigi; Lo Franco, Francesco; Mandrioli, Riccardo; Melaccio, Umberto; Magrassi, Daniele; Neri, Martina; Capelluto, Alessio; Tropeano, Matteo; Gandolfi, Chiara
File in questo prodotto:
File Dimensione Formato  
energies-16-01596_compressed.pdf

accesso aperto

Tipo: Versione (PDF) editoriale
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 1.29 MB
Formato Adobe PDF
1.29 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/914047
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact