BackgroundDifferent methods to measure tissue perfusion are available in equine neonatology, but they are not representative of microvascular derangements. ObjectiveTo evaluate the feasibility of the sidestream dark-field (SDF) capillaroscopy to visualize the capillary microvasculature in conscious newborn foals, the differences between two imaging sites and times of measurements, and the measurements' reproducibility. MethodsSeventeen healthy newborn foals were enrolled. Three sites at the upper and lower lip mucosa were assessed by SDF, using a hand-held capiscope, at 24 h and at 4-5 days after birth. Videos were assessed independently by two observers for quality and for semiquantitative calculation of microvascular parameters, including vascular density (VD), microvascular flow index (MFI), proportion of perfused vessels (PPV), and functional capillary density (FCD). Data were analyzed using unpaired and paired Student's T-tests to assess differences between sites and time-points. Bland-Altman plots and intraclass correlation coefficient (ICC) were used to assess measurement reproducibility. ResultsDifferences were found between the upper and the lower lip for VD at both 24 h and 4-5 days, and for FCD at 24 h, and between the two time-points for PPV at the lower lip. ICC for measurement reproducibility was good for all parameters (0.64-0.79) for the lower lip, and was good for VD and FCD (0,76-0,79) and fair to moderate for MFI and PPV (0.31-0.41) for the upper lip. ConclusionsMeasurement of the capillary microvasculature is feasible in the conscious newborn foal. The lower lip has the best measurement reproducibility. Further investigations are warranted in cardiovascularly compromised cases, particularly in septic foals.

Assessment of the microvascular perfusion using sidestream dark-field imaging in healthy newborn foals / Freccero F.; Di Maio C.; Mariella J.; Lanci A.; Castagnetti C.; Hallowell G.. - In: VETERINARY MEDICINE AND SCIENCE. - ISSN 2053-1095. - ELETTRONICO. - 9:1(2022), pp. 1-9. [10.1002/vms3.1051]

Assessment of the microvascular perfusion using sidestream dark-field imaging in healthy newborn foals

Freccero F.
;
Mariella J.;Lanci A.;Castagnetti C.;
2022

Abstract

BackgroundDifferent methods to measure tissue perfusion are available in equine neonatology, but they are not representative of microvascular derangements. ObjectiveTo evaluate the feasibility of the sidestream dark-field (SDF) capillaroscopy to visualize the capillary microvasculature in conscious newborn foals, the differences between two imaging sites and times of measurements, and the measurements' reproducibility. MethodsSeventeen healthy newborn foals were enrolled. Three sites at the upper and lower lip mucosa were assessed by SDF, using a hand-held capiscope, at 24 h and at 4-5 days after birth. Videos were assessed independently by two observers for quality and for semiquantitative calculation of microvascular parameters, including vascular density (VD), microvascular flow index (MFI), proportion of perfused vessels (PPV), and functional capillary density (FCD). Data were analyzed using unpaired and paired Student's T-tests to assess differences between sites and time-points. Bland-Altman plots and intraclass correlation coefficient (ICC) were used to assess measurement reproducibility. ResultsDifferences were found between the upper and the lower lip for VD at both 24 h and 4-5 days, and for FCD at 24 h, and between the two time-points for PPV at the lower lip. ICC for measurement reproducibility was good for all parameters (0.64-0.79) for the lower lip, and was good for VD and FCD (0,76-0,79) and fair to moderate for MFI and PPV (0.31-0.41) for the upper lip. ConclusionsMeasurement of the capillary microvasculature is feasible in the conscious newborn foal. The lower lip has the best measurement reproducibility. Further investigations are warranted in cardiovascularly compromised cases, particularly in septic foals.
2022
Assessment of the microvascular perfusion using sidestream dark-field imaging in healthy newborn foals / Freccero F.; Di Maio C.; Mariella J.; Lanci A.; Castagnetti C.; Hallowell G.. - In: VETERINARY MEDICINE AND SCIENCE. - ISSN 2053-1095. - ELETTRONICO. - 9:1(2022), pp. 1-9. [10.1002/vms3.1051]
Freccero F.; Di Maio C.; Mariella J.; Lanci A.; Castagnetti C.; Hallowell G.
File in questo prodotto:
File Dimensione Formato  
Veterinary Medicine Sci - 2022 - Freccero - Assessment of the microvascular perfusion using sidestream dark‐field imaging.pdf

accesso aperto

Tipo: Versione (PDF) editoriale
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 422.8 kB
Formato Adobe PDF
422.8 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/911035
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact