Purpose - To evaluate and compare the depth of corneal stromal demarcation line after accelerated collagen crosslinking (CXL) using continuous and pulsed light ultraviolet-A (UVA) exposure. Setting Department of Ophthalmology, Arcispedale Santa Maria Nuova, Reggio Emilia, Italy. Design Retrospective case series. Methods Patients with progressive keratoconus were assigned to 1 of 2 treatment protocols using the same irradiation device for accelerated CXL. Patients assigned to Group A received accelerated CXL using continuous UVA light exposure at 30 mW/cm2 for 4 minutes. Patients assigned to Group B received accelerated CXL using pulsed UVA light with 8 minutes (1 second on/1 second off) of UVA exposure at 30 mW/cm2 and energy dose of 7.2 J/cm2. One month after surgery, corneal stromal demarcation line depth was measured by 2 independent observers using anterior segment optical coherence tomography (AS-OCT). Results A total of 60 patients were assessed. Corneal stromal demarcation line was easily identified on AS-OCT scans in all eyes by both observers. The mean depth of stromal demarcation line was 149.32 ± 36.03 μm in Group A and 213 ± 47.38 μm in Group B. The difference in stromal demarcation line depth between groups was statistically significant (P < .001). Conclusions Using accelerated CXL, the corneal stromal demarcation line was significantly deeper using pulsed rather than continuous light exposure.

Antonio Moramarco, Alfonso Iovieno, Antonio Sartori, FONTANA L (2015). Corneal stromal demarcation line after accelerated crosslinking using continuous and pulsed light. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 41, 2546-2551.

Corneal stromal demarcation line after accelerated crosslinking using continuous and pulsed light

FONTANA L
2015

Abstract

Purpose - To evaluate and compare the depth of corneal stromal demarcation line after accelerated collagen crosslinking (CXL) using continuous and pulsed light ultraviolet-A (UVA) exposure. Setting Department of Ophthalmology, Arcispedale Santa Maria Nuova, Reggio Emilia, Italy. Design Retrospective case series. Methods Patients with progressive keratoconus were assigned to 1 of 2 treatment protocols using the same irradiation device for accelerated CXL. Patients assigned to Group A received accelerated CXL using continuous UVA light exposure at 30 mW/cm2 for 4 minutes. Patients assigned to Group B received accelerated CXL using pulsed UVA light with 8 minutes (1 second on/1 second off) of UVA exposure at 30 mW/cm2 and energy dose of 7.2 J/cm2. One month after surgery, corneal stromal demarcation line depth was measured by 2 independent observers using anterior segment optical coherence tomography (AS-OCT). Results A total of 60 patients were assessed. Corneal stromal demarcation line was easily identified on AS-OCT scans in all eyes by both observers. The mean depth of stromal demarcation line was 149.32 ± 36.03 μm in Group A and 213 ± 47.38 μm in Group B. The difference in stromal demarcation line depth between groups was statistically significant (P < .001). Conclusions Using accelerated CXL, the corneal stromal demarcation line was significantly deeper using pulsed rather than continuous light exposure.
2015
Antonio Moramarco, Alfonso Iovieno, Antonio Sartori, FONTANA L (2015). Corneal stromal demarcation line after accelerated crosslinking using continuous and pulsed light. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 41, 2546-2551.
Antonio Moramarco; Alfonso Iovieno; Antonio Sartori; FONTANA L
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/910596
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 71
  • ???jsp.display-item.citation.isi??? 56
social impact