During a research on the optimization of the mechanical performances of CLT building elements to respond to particular needs for the improvement of seismic design, a measurement campaign of vibration reduction index was carried out on a large-scale test setup. The large scale set up allows to build up to eight adjacent and/or overlaid rooms, performing, eventually, simultaneous measurements of vibration reduction index and sound reduction index according respectively ISO 10848 and ISO 16283 series. At the first stage of the research, a comparison between different connection techniques of CLT building elements was made, with the aim of pointing out interactions between wooden elements and resilient layers connected by different types of fixing systems.

Flanking transmission in CLT buildings: Comparison between vibration reduction index measurements for different mounting conditions / Di Bella A.; Dall'Acqua d'Industria L.; Valluzzi M.R.; Pengo A.; Barbaresi L.; Di Nocco F.; Morandi F.. - ELETTRONICO. - (2019), pp. 1-9. (Intervento presentato al convegno 48th International Congress and Exhibition on Noise Control Engineering, INTER-NOISE 2019 MADRID tenutosi a IFEMA Palacio Municial, esp nel 2019).

Flanking transmission in CLT buildings: Comparison between vibration reduction index measurements for different mounting conditions

Barbaresi L.;Di Nocco F.;Morandi F.
2019

Abstract

During a research on the optimization of the mechanical performances of CLT building elements to respond to particular needs for the improvement of seismic design, a measurement campaign of vibration reduction index was carried out on a large-scale test setup. The large scale set up allows to build up to eight adjacent and/or overlaid rooms, performing, eventually, simultaneous measurements of vibration reduction index and sound reduction index according respectively ISO 10848 and ISO 16283 series. At the first stage of the research, a comparison between different connection techniques of CLT building elements was made, with the aim of pointing out interactions between wooden elements and resilient layers connected by different types of fixing systems.
2019
INTER-NOISE 2019 MADRID - 48th International Congress and Exhibition on Noise Control Engineering
1
9
Flanking transmission in CLT buildings: Comparison between vibration reduction index measurements for different mounting conditions / Di Bella A.; Dall'Acqua d'Industria L.; Valluzzi M.R.; Pengo A.; Barbaresi L.; Di Nocco F.; Morandi F.. - ELETTRONICO. - (2019), pp. 1-9. (Intervento presentato al convegno 48th International Congress and Exhibition on Noise Control Engineering, INTER-NOISE 2019 MADRID tenutosi a IFEMA Palacio Municial, esp nel 2019).
Di Bella A.; Dall'Acqua d'Industria L.; Valluzzi M.R.; Pengo A.; Barbaresi L.; Di Nocco F.; Morandi F.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/908159
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? ND
social impact