The aim of this study was to evaluate the influence of the frequency of mechanical pulses during mechanical fatigue aging on bond strength between glass fiber posts and root dentin. Fiber posts were adhesively cemented in 30 bovine roots and the core was built up with composite. All specimens were subjected to mechanical cycling (45 degrees angle; 37 degrees C; 50N; 2x10(6) pulses) at different frequencies: 2, 4, and 8Hz. After the fatigue, each specimen was submitted to push out test. The bond strength was calculated for data analysis (one-way ANOVA, p=0.05). The frequency did not affect the push-out (p=0.7). The main failure mode was between dentin and cement in all groups. The mechanical pulses were not influenced by the bond strength between root dentin and fiber posts. Thus, it is possible to decrease the time-consuming in vitro tests involving posts without damaging the reliability of the test.
Rippe, M.P., Wandscher, V.F., Bergoli, C.D., Baldissara, P., Ozcan, M., Valandro, L.F. (2016). Effect of the frequency of mechanical pulses for fatigue aging testing on push-out bond strength between glass fiber posts and root dentin. JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 30(11), 1243-1252 [10.1080/01694243.2016.1142805].
Effect of the frequency of mechanical pulses for fatigue aging testing on push-out bond strength between glass fiber posts and root dentin
Baldissara, P;
2016
Abstract
The aim of this study was to evaluate the influence of the frequency of mechanical pulses during mechanical fatigue aging on bond strength between glass fiber posts and root dentin. Fiber posts were adhesively cemented in 30 bovine roots and the core was built up with composite. All specimens were subjected to mechanical cycling (45 degrees angle; 37 degrees C; 50N; 2x10(6) pulses) at different frequencies: 2, 4, and 8Hz. After the fatigue, each specimen was submitted to push out test. The bond strength was calculated for data analysis (one-way ANOVA, p=0.05). The frequency did not affect the push-out (p=0.7). The main failure mode was between dentin and cement in all groups. The mechanical pulses were not influenced by the bond strength between root dentin and fiber posts. Thus, it is possible to decrease the time-consuming in vitro tests involving posts without damaging the reliability of the test.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.