The aim of this study was to evaluate the influence of the frequency of mechanical pulses during mechanical fatigue aging on bond strength between glass fiber posts and root dentin. Fiber posts were adhesively cemented in 30 bovine roots and the core was built up with composite. All specimens were subjected to mechanical cycling (45 degrees angle; 37 degrees C; 50N; 2x10(6) pulses) at different frequencies: 2, 4, and 8Hz. After the fatigue, each specimen was submitted to push out test. The bond strength was calculated for data analysis (one-way ANOVA, p=0.05). The frequency did not affect the push-out (p=0.7). The main failure mode was between dentin and cement in all groups. The mechanical pulses were not influenced by the bond strength between root dentin and fiber posts. Thus, it is possible to decrease the time-consuming in vitro tests involving posts without damaging the reliability of the test.

Effect of the frequency of mechanical pulses for fatigue aging testing on push-out bond strength between glass fiber posts and root dentin / Rippe, MP; Wandscher, VF; Bergoli, CD; Baldissara, P; Ozcan, M; Valandro, LF. - In: JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY. - ISSN 0169-4243. - STAMPA. - 30:11(2016), pp. 1243-1252. [10.1080/01694243.2016.1142805]

Effect of the frequency of mechanical pulses for fatigue aging testing on push-out bond strength between glass fiber posts and root dentin

Baldissara, P;
2016

Abstract

The aim of this study was to evaluate the influence of the frequency of mechanical pulses during mechanical fatigue aging on bond strength between glass fiber posts and root dentin. Fiber posts were adhesively cemented in 30 bovine roots and the core was built up with composite. All specimens were subjected to mechanical cycling (45 degrees angle; 37 degrees C; 50N; 2x10(6) pulses) at different frequencies: 2, 4, and 8Hz. After the fatigue, each specimen was submitted to push out test. The bond strength was calculated for data analysis (one-way ANOVA, p=0.05). The frequency did not affect the push-out (p=0.7). The main failure mode was between dentin and cement in all groups. The mechanical pulses were not influenced by the bond strength between root dentin and fiber posts. Thus, it is possible to decrease the time-consuming in vitro tests involving posts without damaging the reliability of the test.
2016
Effect of the frequency of mechanical pulses for fatigue aging testing on push-out bond strength between glass fiber posts and root dentin / Rippe, MP; Wandscher, VF; Bergoli, CD; Baldissara, P; Ozcan, M; Valandro, LF. - In: JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY. - ISSN 0169-4243. - STAMPA. - 30:11(2016), pp. 1243-1252. [10.1080/01694243.2016.1142805]
Rippe, MP; Wandscher, VF; Bergoli, CD; Baldissara, P; Ozcan, M; Valandro, LF
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/907727
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact