BackgroundThe quality of gastrointestinal (GI) endoscopy has been recently identified as a major priority being associated with many outcomes and patient's experience. ObjectiveTo assess adherence of endoscopists to the European Society of Gastrointestinal Endoscopy (ESGE) quality performance measures for upper and lower GI endoscopy in Italy. MethodsAll endoscopist members of the Italian Society of Digestive Endoscopy (SIED) were invited from October 2018 to December 2018 to participate to a self-administered questionnaire-based survey. The questionnaire included questions on demographics and professional characteristics, and the recent ESGE quality performance measures for upper and lower GI endoscopy. ResultsA total of 392 endoscopists participated in the study. Only a minority (18.2%) of participants recorded the duration of esophagogastroduodenoscopy (EGD) and 51% provided accurate photo documentation in the minimum standard of 90% of cases. Almost all endoscopists correctly used Prague and Los Angeles classifications (87.8% and 98.2%, respectively), as well as Seattle and Management of precancerous conditions and lesions in the stomach (MAPS) biopsy protocols (86.5% and 91.4%, respectively). However, only 52.8% of participants monitored complications after therapeutic EGD, and 40.8% recorded patients with a diagnosis of Barrett's esophagus (BE). With regard to colonoscopy, almost all endoscopists (93.9%) used the Boston Bowel Preparation Scale for measuring bowel preparation quality and reported a cecal intubation rate >= 90%. However, about a quarter (26.2%) of participants reported an adenoma detection rate of <25%, only 52.8% applied an appropriate polypectomy technique, 48% monitored complications after the procedure, and 12.4% measured patient's experience. ConclusionThe adherence of endoscopists to ESGE performance measures for GI endoscopy is sub-optimal in Italy. There is a need to disseminate and implement performance measures and endorse educational and scientific interventions on the quality of endoscopy.

Adherence to European Society of Gastrointestinal Endoscopy Quality Performance Measures for Upper and Lower Gastrointestinal Endoscopy: A Nationwide Survey From the Italian Society of Digestive Endoscopy / Zagari, Rocco Maurizio; Frazzoni, Leonardo; Fuccio, Lorenzo; Bertani, Helga; Crinò, Stefano Francesco; Magarotto, Andrea; Dajti, Elton; Tringali, Andrea; Da Massa Carrara, Paola; Cengia, Gianpaolo; Ciliberto, Enrico; Conigliaro, Rita; Germanà, Bastianello; Lamazza, Antonietta; Pisani, Antonio; Spinzi, Giancarlo; Capelli, Maurizio; Bazzoli, Franco; Pasquale, Luigi. - In: FRONTIERS IN MEDICINE. - ISSN 2296-858X. - STAMPA. - 9:(2022), pp. 868449.1-868449.10. [10.3389/fmed.2022.868449]

Adherence to European Society of Gastrointestinal Endoscopy Quality Performance Measures for Upper and Lower Gastrointestinal Endoscopy: A Nationwide Survey From the Italian Society of Digestive Endoscopy

Zagari, Rocco Maurizio
;
Fuccio, Lorenzo;Dajti, Elton;Capelli, Maurizio;Bazzoli, Franco;
2022

Abstract

BackgroundThe quality of gastrointestinal (GI) endoscopy has been recently identified as a major priority being associated with many outcomes and patient's experience. ObjectiveTo assess adherence of endoscopists to the European Society of Gastrointestinal Endoscopy (ESGE) quality performance measures for upper and lower GI endoscopy in Italy. MethodsAll endoscopist members of the Italian Society of Digestive Endoscopy (SIED) were invited from October 2018 to December 2018 to participate to a self-administered questionnaire-based survey. The questionnaire included questions on demographics and professional characteristics, and the recent ESGE quality performance measures for upper and lower GI endoscopy. ResultsA total of 392 endoscopists participated in the study. Only a minority (18.2%) of participants recorded the duration of esophagogastroduodenoscopy (EGD) and 51% provided accurate photo documentation in the minimum standard of 90% of cases. Almost all endoscopists correctly used Prague and Los Angeles classifications (87.8% and 98.2%, respectively), as well as Seattle and Management of precancerous conditions and lesions in the stomach (MAPS) biopsy protocols (86.5% and 91.4%, respectively). However, only 52.8% of participants monitored complications after therapeutic EGD, and 40.8% recorded patients with a diagnosis of Barrett's esophagus (BE). With regard to colonoscopy, almost all endoscopists (93.9%) used the Boston Bowel Preparation Scale for measuring bowel preparation quality and reported a cecal intubation rate >= 90%. However, about a quarter (26.2%) of participants reported an adenoma detection rate of <25%, only 52.8% applied an appropriate polypectomy technique, 48% monitored complications after the procedure, and 12.4% measured patient's experience. ConclusionThe adherence of endoscopists to ESGE performance measures for GI endoscopy is sub-optimal in Italy. There is a need to disseminate and implement performance measures and endorse educational and scientific interventions on the quality of endoscopy.
2022
Adherence to European Society of Gastrointestinal Endoscopy Quality Performance Measures for Upper and Lower Gastrointestinal Endoscopy: A Nationwide Survey From the Italian Society of Digestive Endoscopy / Zagari, Rocco Maurizio; Frazzoni, Leonardo; Fuccio, Lorenzo; Bertani, Helga; Crinò, Stefano Francesco; Magarotto, Andrea; Dajti, Elton; Tringali, Andrea; Da Massa Carrara, Paola; Cengia, Gianpaolo; Ciliberto, Enrico; Conigliaro, Rita; Germanà, Bastianello; Lamazza, Antonietta; Pisani, Antonio; Spinzi, Giancarlo; Capelli, Maurizio; Bazzoli, Franco; Pasquale, Luigi. - In: FRONTIERS IN MEDICINE. - ISSN 2296-858X. - STAMPA. - 9:(2022), pp. 868449.1-868449.10. [10.3389/fmed.2022.868449]
Zagari, Rocco Maurizio; Frazzoni, Leonardo; Fuccio, Lorenzo; Bertani, Helga; Crinò, Stefano Francesco; Magarotto, Andrea; Dajti, Elton; Tringali, Andrea; Da Massa Carrara, Paola; Cengia, Gianpaolo; Ciliberto, Enrico; Conigliaro, Rita; Germanà, Bastianello; Lamazza, Antonietta; Pisani, Antonio; Spinzi, Giancarlo; Capelli, Maurizio; Bazzoli, Franco; Pasquale, Luigi
File in questo prodotto:
File Dimensione Formato  
Zagari quality survey FISMAD - Front Med 2022.pdf

accesso aperto

Tipo: Versione (PDF) editoriale
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 240.76 kB
Formato Adobe PDF
240.76 kB Adobe PDF Visualizza/Apri
Table_1_Adherence to European Society of Gastrointestinal Endoscopy Quality Performance Measures for Upper and Lower Gastrointestinal Endoscopy_ A Nat.DOCX

accesso aperto

Tipo: File Supplementare
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 20.33 kB
Formato Microsoft Word XML
20.33 kB Microsoft Word XML Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/906082
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 4
social impact