(1) Background: Leadless (LL) stimulation is perceived to lower surgical, vascular, and lead-related complications compared to transvenous (TV) pacemakers, yet controlled studies are lacking and real-life experience is non-conclusive. (2) Aim: To prospectively analyse survival and complication rates in leadless versus transvenous VVIR pacemakers. (3) Methods: Prospective analysis of mortality and complications in 344 consecutive VVIR TV and LL pacemaker recipients between June 2015 and May 2021. Indications for VVIR pacing were “slow” AF, atrio-ventricular block in AF or in sinus rhythm in bedridden cognitively impaired patients. LL indication was based on individualised clinical judgement. (4) Results: 72 patients received LL and 272 TV VVIR pacemakers. LL pacemaker indications included ongoing/expected chronic haemodialysis, superior venous access issues, active lifestyle with low pacing percentage expected, frailty causing high bleeding/infectious risk, previous valvular endocarditis, or device infection requiring extraction. No significant difference in the overall acute and long-term complication rate was observed between LL and TV cohorts, with greater mortality occurring in TV due to selection of older patients. (5) Conclusions: Given the low complication rate and life expectancy in this contemporary VVIR cohort, extending LL indications to all VVIR candidates is unlikely to provide clear-cut benefits. Considering the higher costs of LL technology, careful patient selection is mandatory for LL PMs to become advantageous, i.e., in the presence of vascular access issues, high bleeding/infectious risk, and long life expectancy, rendering lead-related issues and repeated surgery relevant in the long-term perspective.

Bertelli M., Toniolo S., Ziacchi M., Gasperetti A., Schiavone M., Arosio R., et al. (2022). Is Less Always More? A Prospective Two-Centre Study Addressing Clinical Outcomes in Leadless versus Transvenous Single-Chamber Pacemaker Recipients. JOURNAL OF CLINICAL MEDICINE, 11(20), 1-11 [10.3390/jcm11206071].

Is Less Always More? A Prospective Two-Centre Study Addressing Clinical Outcomes in Leadless versus Transvenous Single-Chamber Pacemaker Recipients

Bertelli M.;Toniolo S.;Ziacchi M.;Statuto G.;Angeletti A.;Martignani C.;Diemberger I.;
2022

Abstract

(1) Background: Leadless (LL) stimulation is perceived to lower surgical, vascular, and lead-related complications compared to transvenous (TV) pacemakers, yet controlled studies are lacking and real-life experience is non-conclusive. (2) Aim: To prospectively analyse survival and complication rates in leadless versus transvenous VVIR pacemakers. (3) Methods: Prospective analysis of mortality and complications in 344 consecutive VVIR TV and LL pacemaker recipients between June 2015 and May 2021. Indications for VVIR pacing were “slow” AF, atrio-ventricular block in AF or in sinus rhythm in bedridden cognitively impaired patients. LL indication was based on individualised clinical judgement. (4) Results: 72 patients received LL and 272 TV VVIR pacemakers. LL pacemaker indications included ongoing/expected chronic haemodialysis, superior venous access issues, active lifestyle with low pacing percentage expected, frailty causing high bleeding/infectious risk, previous valvular endocarditis, or device infection requiring extraction. No significant difference in the overall acute and long-term complication rate was observed between LL and TV cohorts, with greater mortality occurring in TV due to selection of older patients. (5) Conclusions: Given the low complication rate and life expectancy in this contemporary VVIR cohort, extending LL indications to all VVIR candidates is unlikely to provide clear-cut benefits. Considering the higher costs of LL technology, careful patient selection is mandatory for LL PMs to become advantageous, i.e., in the presence of vascular access issues, high bleeding/infectious risk, and long life expectancy, rendering lead-related issues and repeated surgery relevant in the long-term perspective.
2022
Bertelli M., Toniolo S., Ziacchi M., Gasperetti A., Schiavone M., Arosio R., et al. (2022). Is Less Always More? A Prospective Two-Centre Study Addressing Clinical Outcomes in Leadless versus Transvenous Single-Chamber Pacemaker Recipients. JOURNAL OF CLINICAL MEDICINE, 11(20), 1-11 [10.3390/jcm11206071].
Bertelli M.; Toniolo S.; Ziacchi M.; Gasperetti A.; Schiavone M.; Arosio R.; Capobianco C.; Mitacchione G.; Statuto G.; Angeletti A.; Martignani C.; D...espandi
File in questo prodotto:
File Dimensione Formato  
jcm-11-06071.pdf

accesso aperto

Tipo: Versione (PDF) editoriale
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 773.43 kB
Formato Adobe PDF
773.43 kB Adobe PDF Visualizza/Apri
jcm-11-06071-s001.zip

accesso aperto

Tipo: File Supplementare
Licenza: Licenza per Accesso Aperto. Altra tipologia di licenza compatibile con Open Access
Dimensione 36.93 MB
Formato Zip File
36.93 MB Zip File Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/903630
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 7
social impact