Background and Aims: Evidence is limited on the comparative diagnostic performance of newer end-cutting fine-needle biopsy (FNB) needles for tissue sampling of pancreatic masses. We performed a systematic review with network meta-analysis to compare the diagnostic accuracy of available FNB needles for sampling of solid pancreatic lesions. Methods: A systematic literature review (Medline and Cochrane Database) was conducted for studies evaluating the accuracy of newer FNB needles in adults undergoing EUS-guided sampling of solid pancreatic masses. The primary outcome was diagnostic accuracy. Secondary outcomes were sample adequacy, diagnostic sensitivity, specificity, and adverse event rate. We performed pairwise and network meta-analyses and appraised the quality of evidence using Grading of Recommendations Assessment, Development and Evaluation methodology. Results: Overall, 16 RCTs (1934 patients) were identified. On network meta-analysis, Franseen needles (Acquire; Boston Scientific, Marlborough, Mass, USA) significantly outperformed reverse-bevel needles (risk ratio [RR], 1.21 [95% confidence interval {CI}, 1.05-1.40] for accuracy and 1.31 [95% CI, 1.05-1.22] for adequacy) and FNAneedles (RR, 1.21 [95% CI, 1.01-1.25] for accuracy and 1.07 [95% CI, 1.02-1.13] for adequacy). Likewise, the Forktip needle (SharkCore; Medtronic, Dublin, Ireland) was significantly superior to the reverse-bevel needle (RR, 1.17 [95% CI, 1.03-1.33] for accuracy and 1.09 [95% CI, 1.02-1.16] for adequacy) and to the FNA needle (RR, 1.09 [95% CI, 1.01-1.19] for accuracy and 1.03 [95% CI, 1.01-1.07] for adequacy). Other comparisons did not achieve statistical significance. As a consequence, Franseen (surface under the cumulative ranking score, .89 for accuracy and .94 for adequacy) and Fork-tip needles (surface under the cumulative ranking score, .76 for accuracy and .73 for adequacy) ranked as the 2 highest-performing FNB needles. When considering different needle sizes, 25-gauge Franseen and 25-gauge Fork-tip needles were not superior to 22-gauge reverse-bevel needles (RR, 1.18 [95% CI, .96-1.46] and 1.04 [95% CI, .62-1.52]). None of the tested needles was significantly superior to the other FNB devices or to FNA needles when rapid onsite cytologic evaluation was available. Conclusions: Franseen and Fork-tip needles, particularly 22-gauge size, showed the highest performance for tissue sampling of pancreatic masses, with low confidence in estimates

Gkolfakis P., Crino S.F., Tziatzios G., Ramai D., Papaefthymiou A., Papanikolaou I.S., et al. (2022). Comparative diagnostic performance of end-cutting fine-needle biopsy needles for EUS tissue sampling of solid pancreatic masses: a network meta-analysis. GASTROINTESTINAL ENDOSCOPY, 95, 1067-1077 [10.1016/j.gie.2022.01.019].

Comparative diagnostic performance of end-cutting fine-needle biopsy needles for EUS tissue sampling of solid pancreatic masses: a network meta-analysis

Lisotti A.;Fusaroli P.;
2022

Abstract

Background and Aims: Evidence is limited on the comparative diagnostic performance of newer end-cutting fine-needle biopsy (FNB) needles for tissue sampling of pancreatic masses. We performed a systematic review with network meta-analysis to compare the diagnostic accuracy of available FNB needles for sampling of solid pancreatic lesions. Methods: A systematic literature review (Medline and Cochrane Database) was conducted for studies evaluating the accuracy of newer FNB needles in adults undergoing EUS-guided sampling of solid pancreatic masses. The primary outcome was diagnostic accuracy. Secondary outcomes were sample adequacy, diagnostic sensitivity, specificity, and adverse event rate. We performed pairwise and network meta-analyses and appraised the quality of evidence using Grading of Recommendations Assessment, Development and Evaluation methodology. Results: Overall, 16 RCTs (1934 patients) were identified. On network meta-analysis, Franseen needles (Acquire; Boston Scientific, Marlborough, Mass, USA) significantly outperformed reverse-bevel needles (risk ratio [RR], 1.21 [95% confidence interval {CI}, 1.05-1.40] for accuracy and 1.31 [95% CI, 1.05-1.22] for adequacy) and FNAneedles (RR, 1.21 [95% CI, 1.01-1.25] for accuracy and 1.07 [95% CI, 1.02-1.13] for adequacy). Likewise, the Forktip needle (SharkCore; Medtronic, Dublin, Ireland) was significantly superior to the reverse-bevel needle (RR, 1.17 [95% CI, 1.03-1.33] for accuracy and 1.09 [95% CI, 1.02-1.16] for adequacy) and to the FNA needle (RR, 1.09 [95% CI, 1.01-1.19] for accuracy and 1.03 [95% CI, 1.01-1.07] for adequacy). Other comparisons did not achieve statistical significance. As a consequence, Franseen (surface under the cumulative ranking score, .89 for accuracy and .94 for adequacy) and Fork-tip needles (surface under the cumulative ranking score, .76 for accuracy and .73 for adequacy) ranked as the 2 highest-performing FNB needles. When considering different needle sizes, 25-gauge Franseen and 25-gauge Fork-tip needles were not superior to 22-gauge reverse-bevel needles (RR, 1.18 [95% CI, .96-1.46] and 1.04 [95% CI, .62-1.52]). None of the tested needles was significantly superior to the other FNB devices or to FNA needles when rapid onsite cytologic evaluation was available. Conclusions: Franseen and Fork-tip needles, particularly 22-gauge size, showed the highest performance for tissue sampling of pancreatic masses, with low confidence in estimates
2022
Gkolfakis P., Crino S.F., Tziatzios G., Ramai D., Papaefthymiou A., Papanikolaou I.S., et al. (2022). Comparative diagnostic performance of end-cutting fine-needle biopsy needles for EUS tissue sampling of solid pancreatic masses: a network meta-analysis. GASTROINTESTINAL ENDOSCOPY, 95, 1067-1077 [10.1016/j.gie.2022.01.019].
Gkolfakis P.; Crino S.F.; Tziatzios G.; Ramai D.; Papaefthymiou A.; Papanikolaou I.S.; Triantafyllou K.; Arvanitakis M.; Lisotti A.; Fusaroli P.; Mang...espandi
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/902146
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 81
  • ???jsp.display-item.citation.isi??? 75
social impact