The selected device for the ALICE Time-of-Flight array is the Multigap Resistive Plate Chamber (MRPC). We have tested this device at the Gamma Irradiation Facility at CERN to evaluate the rate dependence. We find that the rate capability ofthe MRPC easily exceeds the 50 Hz/cm2 maximum expected rate at the ALICE experiment. In addition, we have measured the power dissipated for an equivalent flux of 1.6 kHz/cm2 ofthrough-going muons to be 650 mW/m2.
Akindinov A., Alici A., Anselmo F., Antonioli P., Baek Y., Basile M., et al. (2002). A study of the multigap RPC at the gamma irradiation facility at CERN. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 490(1-2), 58-70 [10.1016/S0168-9002(02)00918-X].
A study of the multigap RPC at the gamma irradiation facility at CERN
Alici A.;Cifarelli L.;Scioli G.;Zichichi A.
2002
Abstract
The selected device for the ALICE Time-of-Flight array is the Multigap Resistive Plate Chamber (MRPC). We have tested this device at the Gamma Irradiation Facility at CERN to evaluate the rate dependence. We find that the rate capability ofthe MRPC easily exceeds the 50 Hz/cm2 maximum expected rate at the ALICE experiment. In addition, we have measured the power dissipated for an equivalent flux of 1.6 kHz/cm2 ofthrough-going muons to be 650 mW/m2.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.