Purpose. The purpose of this study is to compare the functional and clinical outcomes, blood loss, complication rate, and hospital length of stay (LOS) of total hip replacement (THR) using a minimally invasive tissue-sparing posterior superior (TSPS) approach and the standard posterior approach. Materials and Methods. This retrospective, observational, double-centered study included 38 patients undergoing hip replacement. The patents were divided into two groups: control group (19 patients), who underwent surgery with the standard posterior approach, and treatment group (19 patients), who received the same type of implant with ceramic-on-ceramic bearing via the TSPS approach. Hemoglobin level was assessed preoperatively, on first and second postoperative days, and on discharge day. Harris hip score and Western Ontario and McMaster Universities Arthritis Index were used to measure the clinical and functional outcomes. Hospital LOS and incidence of early and late complications were assessed in both groups. Postoperative anteroposterior pelvis X-ray was performed to assess the correct positioning of implants. Results. Better early clinical outcomes (p=0.0155), lesser blood loss (p < 0.0001), and reduced hospital LOS (p < 0.0001) were observed in the TSPS group than in the control group. No major adverse effects occurred in both groups, and a satisfactory implant orientation was achieved in all patients. Conclusions. The TSPS approach is a reliable minimally invasive procedure for THR as it allows an accurate orientation of the components and provides better early postoperative functional outcomes, faster recovery, significantly lower blood loss, and shorter hospital LOS than the standard posterior approach. However, further research is needed to confirm the promising results and cost-effectiveness of the TSPS approach in larger cohorts with a longer follow-up period.
Romagnoli, M., Raggi, F., Roberti di Sarsina, T., Saracco, A., Casali, M., Grassi, A., et al. (2022). Comparison of a Minimally Invasive Tissue-Sparing Posterior Superior (TSPS) Approach and the Standard Posterior Approach for Hip Replacement. BIOMED RESEARCH INTERNATIONAL, 2022, 1-7 [10.1155/2022/3248526].
Comparison of a Minimally Invasive Tissue-Sparing Posterior Superior (TSPS) Approach and the Standard Posterior Approach for Hip Replacement
Romagnoli, Matteo;Raggi, Federico;Roberti di Sarsina, Tommaso;Grassi, Alberto
;Zaffagnini, Stefano
2022
Abstract
Purpose. The purpose of this study is to compare the functional and clinical outcomes, blood loss, complication rate, and hospital length of stay (LOS) of total hip replacement (THR) using a minimally invasive tissue-sparing posterior superior (TSPS) approach and the standard posterior approach. Materials and Methods. This retrospective, observational, double-centered study included 38 patients undergoing hip replacement. The patents were divided into two groups: control group (19 patients), who underwent surgery with the standard posterior approach, and treatment group (19 patients), who received the same type of implant with ceramic-on-ceramic bearing via the TSPS approach. Hemoglobin level was assessed preoperatively, on first and second postoperative days, and on discharge day. Harris hip score and Western Ontario and McMaster Universities Arthritis Index were used to measure the clinical and functional outcomes. Hospital LOS and incidence of early and late complications were assessed in both groups. Postoperative anteroposterior pelvis X-ray was performed to assess the correct positioning of implants. Results. Better early clinical outcomes (p=0.0155), lesser blood loss (p < 0.0001), and reduced hospital LOS (p < 0.0001) were observed in the TSPS group than in the control group. No major adverse effects occurred in both groups, and a satisfactory implant orientation was achieved in all patients. Conclusions. The TSPS approach is a reliable minimally invasive procedure for THR as it allows an accurate orientation of the components and provides better early postoperative functional outcomes, faster recovery, significantly lower blood loss, and shorter hospital LOS than the standard posterior approach. However, further research is needed to confirm the promising results and cost-effectiveness of the TSPS approach in larger cohorts with a longer follow-up period.File | Dimensione | Formato | |
---|---|---|---|
3248526.pdf
accesso aperto
Tipo:
Versione (PDF) editoriale
Licenza:
Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione
1.16 MB
Formato
Adobe PDF
|
1.16 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.