Background: to compare several uterine biometric parameters at transvaginal ultrasound (TVUS) between adenomyosis and non-adenomyosis uteri and evaluate their role for the diagnosis of diffuse adenomyosis. Methods: prospective observational study conducted between the 1 February 2022 and the 30 April 2022. In this case, 56 patients with TVUS diagnosis of adenomyosis were included. A 1:1 ratio age and parity-matched group of non-adenomyosis patients was selected. We compared sonographic uterine biometric parameters (longitudinal (LD), anteroposterior (APD) and transverse (TD) diameters, volume, simple and complex diameter ratios) and investigated their diagnostic performance. Results: all sonographic parameters were significantly different between the study groups, except for TD/(LD+APD). Optimal cut-off values of APD and LD/APD showed the best sensitivity and specificity. APD diameter equal or superior to 39.5 mm (95% CI, 36.2–42.8) had sensitivity of 0.70 (95% CI, 0.57–0.80), specificity of 0.71 (95% CI, 0.59–0.82) and accuracy of 0.75 (95% CI, 0.66–0.84). LD/APD equal or inferior to 2.05 (95% CI, 1.96–2.13) showed sensitivity and specificity of 0.70 (95% CI, 0.57–0.80) each and accuracy of 0.72 (95% CI, 0.62–0.81). Conclusions: several biometric uterine parameters at TVUS in fertile-aged women were statistically different between adenomyosis and non-adenomyosis uteri, though their optimal cut-off values showed low accuracy in diagnosing adenomyosis.
Raimondo, D., Lazzeri, L., Raffone, A., Giorgi, M., Orsini, B., Verrelli, L., et al. (2022). Sonographic Assessment of Uterine Biometry for the Diagnosis of Diffuse Adenomyosis in a Tertiary Outpatient Clinic. JOURNAL OF PERSONALIZED MEDICINE, 12(10), 1-10 [10.3390/jpm12101572].
Sonographic Assessment of Uterine Biometry for the Diagnosis of Diffuse Adenomyosis in a Tertiary Outpatient Clinic
Raimondo, Diego;Raffone, Antonio
;Orsini, Benedetta;Verrelli, Ludovica;Lenzi, Jacopo;De Meis, Lucia;Seracchioli, Renato;Casadio, Paolo
2022
Abstract
Background: to compare several uterine biometric parameters at transvaginal ultrasound (TVUS) between adenomyosis and non-adenomyosis uteri and evaluate their role for the diagnosis of diffuse adenomyosis. Methods: prospective observational study conducted between the 1 February 2022 and the 30 April 2022. In this case, 56 patients with TVUS diagnosis of adenomyosis were included. A 1:1 ratio age and parity-matched group of non-adenomyosis patients was selected. We compared sonographic uterine biometric parameters (longitudinal (LD), anteroposterior (APD) and transverse (TD) diameters, volume, simple and complex diameter ratios) and investigated their diagnostic performance. Results: all sonographic parameters were significantly different between the study groups, except for TD/(LD+APD). Optimal cut-off values of APD and LD/APD showed the best sensitivity and specificity. APD diameter equal or superior to 39.5 mm (95% CI, 36.2–42.8) had sensitivity of 0.70 (95% CI, 0.57–0.80), specificity of 0.71 (95% CI, 0.59–0.82) and accuracy of 0.75 (95% CI, 0.66–0.84). LD/APD equal or inferior to 2.05 (95% CI, 1.96–2.13) showed sensitivity and specificity of 0.70 (95% CI, 0.57–0.80) each and accuracy of 0.72 (95% CI, 0.62–0.81). Conclusions: several biometric uterine parameters at TVUS in fertile-aged women were statistically different between adenomyosis and non-adenomyosis uteri, though their optimal cut-off values showed low accuracy in diagnosing adenomyosis.File | Dimensione | Formato | |
---|---|---|---|
Raimondo-2022-J_Pers_Med.pdf
accesso aperto
Tipo:
Versione (PDF) editoriale
Licenza:
Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione
2.72 MB
Formato
Adobe PDF
|
2.72 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.