This paper presents the results of space charge and partial discharge measurements carried out on enameled wires, specifically designed to be used in electrical motors fed by adjustable speed drives. These procedures here described can provide a useful tool for short-term evaluation of enameled wires, which can give indications also on long-term performance. Partial discharges and space charge accumulation seem to be significantly influenced by the supply voltage waveform features (frequency and shape), with an extent depending on the material itself. Moreover, partial discharge features, as pulse height and inception voltage, depend considerably on space charge accumulation which may occur, e.g., with unipolar waveforms. Both techniques provide considerably different fingerprints of the two tested kinds of wires.

Cavallini A., Conti M., Fabiani D., Montanari G.C. (2001). Evaluation of corona-resistant magnet wires through partial discharge and space charge measurements [10.1109/EEIC.2001.965582].

Evaluation of corona-resistant magnet wires through partial discharge and space charge measurements

Cavallini A.;Fabiani D.;Montanari G. C.
2001

Abstract

This paper presents the results of space charge and partial discharge measurements carried out on enameled wires, specifically designed to be used in electrical motors fed by adjustable speed drives. These procedures here described can provide a useful tool for short-term evaluation of enameled wires, which can give indications also on long-term performance. Partial discharges and space charge accumulation seem to be significantly influenced by the supply voltage waveform features (frequency and shape), with an extent depending on the material itself. Moreover, partial discharge features, as pulse height and inception voltage, depend considerably on space charge accumulation which may occur, e.g., with unipolar waveforms. Both techniques provide considerably different fingerprints of the two tested kinds of wires.
2001
Proceedings of the Electrical/Electronics Insulation Conference
11
16
Cavallini A., Conti M., Fabiani D., Montanari G.C. (2001). Evaluation of corona-resistant magnet wires through partial discharge and space charge measurements [10.1109/EEIC.2001.965582].
Cavallini A.; Conti M.; Fabiani D.; Montanari G.C.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/897555
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact