Aim: To assess the accuracy of low-dose contrast-enhanced time-resolved 3 T magnetic resonance angiography (MRA) for the morphological and functional assessment of vascular malformations (VM), and to evaluate its diagnostic potential for the depiction of treatment-induced changes. Materials and methods: Twenty-five patients with known VM underwent MRA to evaluate the location and extent of lesions and their haemodynamic characteristics. Three-dimensional (3D) T1-weighted time-resolved sequences were acquired following the administration of 0.05 mmol/kg of gadobenate dimeglumine. VM were classified according to their morphology and haemodynamic characteristics. All patients thereafter underwent conventional angiography to confirm the diagnosis and to treat the lesions (embolization or sclerotherapy). Follow-up MRA was performed 30 days after treatment to assess morphological and functional changes. A visual analogue scale (VAS) was used to clinically assess the severity of symptoms before and after therapy. Results: Based on haemodynamic characteristics, VM were classified as predominantly arterial [4 (16%)], artero-venous [19 (76%)] or venous [2 (8%)]. Twenty-three (92%) lesions were classified as high-flow VM and two (8%) as low-flow VM. Intralesional thrombosis was present in 17 (68%) lesions before therapy and in 10 lesions (40%) after therapy. The median VAS scores were 5 ± 1 before treatment and 4 ± 2 after treatment. Very good correlation (Spearman's correlation coefficient: rho = 0.87; p = 0.000) was noted between the reduction of lesion size on follow-up MRA and pain relief as assessed by VAS. Conclusion: Low-dose contrast-enhanced time-resolved 3 T MRA can be used to define morphological and functional aspects of VM accurately during treatment planning and follow-up, and can identify post-therapy changes that positively correlate with treatment outcome. © 2011 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

Low-dose contrast-enhanced time-resolved MR angiography at 3 T: Diagnostic accuracy for treatment planning and follow-up of vascular malformations / Anzidei M.; Cavallo Marincola B.; Napoli A.; Saba L.; Zaccagna F.; Lucatelli P.; Fanelli F.; Bassetti E.; Salvatori F.M.; Catalano C.; Passariello R.. - In: CLINICAL RADIOLOGY. - ISSN 0009-9260. - STAMPA. - 66:12(2011), pp. 1181-1192. [10.1016/j.crad.2011.08.003]

Low-dose contrast-enhanced time-resolved MR angiography at 3 T: Diagnostic accuracy for treatment planning and follow-up of vascular malformations

Zaccagna F.;
2011

Abstract

Aim: To assess the accuracy of low-dose contrast-enhanced time-resolved 3 T magnetic resonance angiography (MRA) for the morphological and functional assessment of vascular malformations (VM), and to evaluate its diagnostic potential for the depiction of treatment-induced changes. Materials and methods: Twenty-five patients with known VM underwent MRA to evaluate the location and extent of lesions and their haemodynamic characteristics. Three-dimensional (3D) T1-weighted time-resolved sequences were acquired following the administration of 0.05 mmol/kg of gadobenate dimeglumine. VM were classified according to their morphology and haemodynamic characteristics. All patients thereafter underwent conventional angiography to confirm the diagnosis and to treat the lesions (embolization or sclerotherapy). Follow-up MRA was performed 30 days after treatment to assess morphological and functional changes. A visual analogue scale (VAS) was used to clinically assess the severity of symptoms before and after therapy. Results: Based on haemodynamic characteristics, VM were classified as predominantly arterial [4 (16%)], artero-venous [19 (76%)] or venous [2 (8%)]. Twenty-three (92%) lesions were classified as high-flow VM and two (8%) as low-flow VM. Intralesional thrombosis was present in 17 (68%) lesions before therapy and in 10 lesions (40%) after therapy. The median VAS scores were 5 ± 1 before treatment and 4 ± 2 after treatment. Very good correlation (Spearman's correlation coefficient: rho = 0.87; p = 0.000) was noted between the reduction of lesion size on follow-up MRA and pain relief as assessed by VAS. Conclusion: Low-dose contrast-enhanced time-resolved 3 T MRA can be used to define morphological and functional aspects of VM accurately during treatment planning and follow-up, and can identify post-therapy changes that positively correlate with treatment outcome. © 2011 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
2011
Low-dose contrast-enhanced time-resolved MR angiography at 3 T: Diagnostic accuracy for treatment planning and follow-up of vascular malformations / Anzidei M.; Cavallo Marincola B.; Napoli A.; Saba L.; Zaccagna F.; Lucatelli P.; Fanelli F.; Bassetti E.; Salvatori F.M.; Catalano C.; Passariello R.. - In: CLINICAL RADIOLOGY. - ISSN 0009-9260. - STAMPA. - 66:12(2011), pp. 1181-1192. [10.1016/j.crad.2011.08.003]
Anzidei M.; Cavallo Marincola B.; Napoli A.; Saba L.; Zaccagna F.; Lucatelli P.; Fanelli F.; Bassetti E.; Salvatori F.M.; Catalano C.; Passariello R.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/872802
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 11
social impact