Radiomics, quantitative feature extraction from radiological images, can improve disease diagnosis and prognostication. However, radiomic features are susceptible to image acquisition and segmentation variability. Ideally, only features robust to these variations would be incorporated into predictive models, for good generalisability. We extracted 93 radiomic features from carotid artery computed tomography angiograms of 41 patients with cerebrovascular events. We tested feature robustness to region-of-interest perturbations, image pre-processing settings and quantisation methods using both single- and multi-slice approaches. We assessed the ability of the most robust features to identify culprit and non-culprit arteries using several machine learning algorithms and report the average area under the curve (AUC) from five-fold cross validation. Multi-slice features were superior to single for producing robust radiomic features (67 vs. 61). The optimal image quantisation method used bin widths of 25 or 30. Incorporating our top 10 non-redundant robust radiomics features into ElasticNet achieved an AUC of 0.73 and accuracy of 69% (compared to carotid calcification alone [AUC: 0.44, accuracy: 46%]). Our results provide key information for introducing carotid CT radiomics into clinical practice. If validated prospectively, our robust carotid radiomic set could improve stroke prediction and target therapies to those at highest risk.

Le E.P.V., Rundo L., Tarkin J.M., Evans N.R., Chowdhury M.M., Coughlin P.A., et al. (2021). Assessing robustness of carotid artery CT angiography radiomics in the identification of culprit lesions in cerebrovascular events. SCIENTIFIC REPORTS, 11(1), 1-14 [10.1038/s41598-021-82760-w].

Assessing robustness of carotid artery CT angiography radiomics in the identification of culprit lesions in cerebrovascular events

Zaccagna F.;
2021

Abstract

Radiomics, quantitative feature extraction from radiological images, can improve disease diagnosis and prognostication. However, radiomic features are susceptible to image acquisition and segmentation variability. Ideally, only features robust to these variations would be incorporated into predictive models, for good generalisability. We extracted 93 radiomic features from carotid artery computed tomography angiograms of 41 patients with cerebrovascular events. We tested feature robustness to region-of-interest perturbations, image pre-processing settings and quantisation methods using both single- and multi-slice approaches. We assessed the ability of the most robust features to identify culprit and non-culprit arteries using several machine learning algorithms and report the average area under the curve (AUC) from five-fold cross validation. Multi-slice features were superior to single for producing robust radiomic features (67 vs. 61). The optimal image quantisation method used bin widths of 25 or 30. Incorporating our top 10 non-redundant robust radiomics features into ElasticNet achieved an AUC of 0.73 and accuracy of 69% (compared to carotid calcification alone [AUC: 0.44, accuracy: 46%]). Our results provide key information for introducing carotid CT radiomics into clinical practice. If validated prospectively, our robust carotid radiomic set could improve stroke prediction and target therapies to those at highest risk.
2021
Le E.P.V., Rundo L., Tarkin J.M., Evans N.R., Chowdhury M.M., Coughlin P.A., et al. (2021). Assessing robustness of carotid artery CT angiography radiomics in the identification of culprit lesions in cerebrovascular events. SCIENTIFIC REPORTS, 11(1), 1-14 [10.1038/s41598-021-82760-w].
Le E.P.V.; Rundo L.; Tarkin J.M.; Evans N.R.; Chowdhury M.M.; Coughlin P.A.; Pavey H.; Wall C.; Zaccagna F.; Gallagher F.A.; Huang Y.; Sriranjan R.; L...espandi
File in questo prodotto:
File Dimensione Formato  
Assessing robustness of carotid artery CT angiography radiomics in the identification of culprit lesions in cerebrovascular events.pdf

accesso aperto

Tipo: Versione (PDF) editoriale
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 2.38 MB
Formato Adobe PDF
2.38 MB Adobe PDF Visualizza/Apri
41598_2021_82760_MOESM1_ESM.docx

accesso aperto

Tipo: File Supplementare
Licenza: Licenza per accesso libero gratuito
Dimensione 2.75 MB
Formato Microsoft Word XML
2.75 MB Microsoft Word XML Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/871835
Citazioni
  • ???jsp.display-item.citation.pmc??? 17
  • Scopus 33
  • ???jsp.display-item.citation.isi??? 28
social impact