Background: In edentulous patients, bone resorption cannot allow the installation of standard implants and it is demanded to use short implants in the residual alveolar bone or longer implants in grafted bone. Aim: To compare the survival and bone level changes of standard plus short 4-mm implants used as distal support of a maxillary full-arch fixed dental prostheses (FDPs) with standard (10-mm) implants placed in association with a bilateral sinus floor augmentation procedure. Material and Methods: Full-arch FDPs supported by six implants were randomly placed in both groups. In the control group, all implants were 10 mm long and 4.1 mm in diameter. The distal implant in both sides of the maxilla was installed after 4 months from bilaterally sinus floor elevation. In the test group (short group), the distal implant in both sides of the maxilla was 4 mm long and 4.1 mm in diameter. No sinus floor elevations were performed in the test group. Clinical assessments and X-rays were taken at prosthesis delivering and after 6, 12, 18, and 24 months. Patient-reported outcome measures (PROMs) were also evaluated before surgery and after 6, 12, and 24 months. Results: The changes over time of the bone level for the short implants were −0.01 ± 0.11 mm, −0.04 ± 0.13 mm, −0.17 ± 0.29 mm, and −0.28 ± 0.37 mm after 6, 12, 18, and 24 months from prosthesis delivering, respectively. For the standard implants, bone changes were −0.21 ± 0.33 mm (p = 0.103), −0.30 ± 0.32 mm (p = 0.023), −0.40 ± 0.37 mm (p = 0.144), and −0.54 ± 0.49 mm (p = 0.128), respectively. A statistically relevant difference was found only at 12 months after loading between the two groups. Conclusions: Similar results on implant survival rate and mar-ginal bone loss were observed for the short and standard implants, placed in association with a bilateral sinus floor augmentation procedure, used as distal support of a maxillary full-arch FDP. A statistically relevant difference was found only at 12 months after loading between the two groups (p = 0.023).

Rossi F., Tuci L., Ferraioli L., Ricci E., Suerica A., Botticelli D., et al. (2021). Two-year follow-up of 4-mm-long implants used as distal support of full-arch fdps compared to 10-mm implants installed after sinus floor elevation. A randomized clinical trial. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 18(7), 1-12 [10.3390/ijerph18073846].

Two-year follow-up of 4-mm-long implants used as distal support of full-arch fdps compared to 10-mm implants installed after sinus floor elevation. A randomized clinical trial

Pellegrino G.
;
Felice P.
2021

Abstract

Background: In edentulous patients, bone resorption cannot allow the installation of standard implants and it is demanded to use short implants in the residual alveolar bone or longer implants in grafted bone. Aim: To compare the survival and bone level changes of standard plus short 4-mm implants used as distal support of a maxillary full-arch fixed dental prostheses (FDPs) with standard (10-mm) implants placed in association with a bilateral sinus floor augmentation procedure. Material and Methods: Full-arch FDPs supported by six implants were randomly placed in both groups. In the control group, all implants were 10 mm long and 4.1 mm in diameter. The distal implant in both sides of the maxilla was installed after 4 months from bilaterally sinus floor elevation. In the test group (short group), the distal implant in both sides of the maxilla was 4 mm long and 4.1 mm in diameter. No sinus floor elevations were performed in the test group. Clinical assessments and X-rays were taken at prosthesis delivering and after 6, 12, 18, and 24 months. Patient-reported outcome measures (PROMs) were also evaluated before surgery and after 6, 12, and 24 months. Results: The changes over time of the bone level for the short implants were −0.01 ± 0.11 mm, −0.04 ± 0.13 mm, −0.17 ± 0.29 mm, and −0.28 ± 0.37 mm after 6, 12, 18, and 24 months from prosthesis delivering, respectively. For the standard implants, bone changes were −0.21 ± 0.33 mm (p = 0.103), −0.30 ± 0.32 mm (p = 0.023), −0.40 ± 0.37 mm (p = 0.144), and −0.54 ± 0.49 mm (p = 0.128), respectively. A statistically relevant difference was found only at 12 months after loading between the two groups. Conclusions: Similar results on implant survival rate and mar-ginal bone loss were observed for the short and standard implants, placed in association with a bilateral sinus floor augmentation procedure, used as distal support of a maxillary full-arch FDP. A statistically relevant difference was found only at 12 months after loading between the two groups (p = 0.023).
2021
Rossi F., Tuci L., Ferraioli L., Ricci E., Suerica A., Botticelli D., et al. (2021). Two-year follow-up of 4-mm-long implants used as distal support of full-arch fdps compared to 10-mm implants installed after sinus floor elevation. A randomized clinical trial. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 18(7), 1-12 [10.3390/ijerph18073846].
Rossi F.; Tuci L.; Ferraioli L.; Ricci E.; Suerica A.; Botticelli D.; Pellegrino G.; Felice P.
File in questo prodotto:
File Dimensione Formato  
2021 - Posterior short vs long RCT - Rossi_IJERPH.pdf

accesso aperto

Tipo: Versione (PDF) editoriale
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 3.21 MB
Formato Adobe PDF
3.21 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/870818
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 3
social impact