In orthognathic surgery, patient-specific osteosynthesis implants (PSIs) represent a novel approach for the reproduction of the virtual surgical planning on the patient. The aim of this study is to analyse the quality of maxillo-mandibular positioning using a hybrid mandible-first mandibular-PSI-guided procedure on twenty-two patients while the upper maxilla was fixed using manually bent stock titanium miniplates. The virtual surgical plan was used to design PSIs and positioning guides, which were then 3D printed using biocompatible materials. A Cone Beam Computed Tomography (CBCT) scan was performed one month after surgery and postoperative facial skeletal models were segmented for comparison against the surgical plan. A three-dimensional cephalometric analysis was carried out on both planned and obtained anatomies. A Spearman correlation matrix was computed on the calculated discrepancies in order to achieve a more comprehensive description of maxillo-mandibular displacement. Intraoperatively, all PSIs were successfully applied. The procedure was found to be accurate in planned maxillo-mandibular positioning reproduction, while maintaining a degree of flexibility to allow for aesthetics-based verticality correction in a pitch range between -5.31 and +1.79 mm. Such a correction did not significantly affect the achievement of planned frontal symmetry.

PSI-GUIDED MANDIBLE-FIRST ORTHOGNATHIC SURGERY: MAXILLO-MANDIBULAR POSITION ACCURACY AND VERTICAL DIMENSION ADJUSTABILITY / Badiali G, Bevini M, Lunari O, Lovero E, Ruggiero F, Bolognesi F, Feraboli L, Bianchi A, Marchetti C.. - In: JOURNAL OF PERSONALIZED MEDICINE. - ISSN 2075-4426. - ELETTRONICO. - 11:11(2021), pp. 1237.1-1237.12. [10.3390/jpm11111237]

PSI-GUIDED MANDIBLE-FIRST ORTHOGNATHIC SURGERY: MAXILLO-MANDIBULAR POSITION ACCURACY AND VERTICAL DIMENSION ADJUSTABILITY.

Badiali G
Primo
Writing – Review & Editing
;
Bevini M;Lovero E;Ruggiero F;Bolognesi F;Bianchi A;Marchetti C.
2021

Abstract

In orthognathic surgery, patient-specific osteosynthesis implants (PSIs) represent a novel approach for the reproduction of the virtual surgical planning on the patient. The aim of this study is to analyse the quality of maxillo-mandibular positioning using a hybrid mandible-first mandibular-PSI-guided procedure on twenty-two patients while the upper maxilla was fixed using manually bent stock titanium miniplates. The virtual surgical plan was used to design PSIs and positioning guides, which were then 3D printed using biocompatible materials. A Cone Beam Computed Tomography (CBCT) scan was performed one month after surgery and postoperative facial skeletal models were segmented for comparison against the surgical plan. A three-dimensional cephalometric analysis was carried out on both planned and obtained anatomies. A Spearman correlation matrix was computed on the calculated discrepancies in order to achieve a more comprehensive description of maxillo-mandibular displacement. Intraoperatively, all PSIs were successfully applied. The procedure was found to be accurate in planned maxillo-mandibular positioning reproduction, while maintaining a degree of flexibility to allow for aesthetics-based verticality correction in a pitch range between -5.31 and +1.79 mm. Such a correction did not significantly affect the achievement of planned frontal symmetry.
2021
PSI-GUIDED MANDIBLE-FIRST ORTHOGNATHIC SURGERY: MAXILLO-MANDIBULAR POSITION ACCURACY AND VERTICAL DIMENSION ADJUSTABILITY / Badiali G, Bevini M, Lunari O, Lovero E, Ruggiero F, Bolognesi F, Feraboli L, Bianchi A, Marchetti C.. - In: JOURNAL OF PERSONALIZED MEDICINE. - ISSN 2075-4426. - ELETTRONICO. - 11:11(2021), pp. 1237.1-1237.12. [10.3390/jpm11111237]
Badiali G, Bevini M, Lunari O, Lovero E, Ruggiero F, Bolognesi F, Feraboli L, Bianchi A, Marchetti C.
File in questo prodotto:
File Dimensione Formato  
jpm-11-01237-v2-1.pdf

accesso aperto

Tipo: Versione (PDF) editoriale
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 2.9 MB
Formato Adobe PDF
2.9 MB Adobe PDF Visualizza/Apri
jpm-11-01237-s001.zip

accesso aperto

Tipo: File Supplementare
Licenza: Licenza per accesso libero gratuito
Dimensione 28.98 kB
Formato Zip File
28.98 kB Zip File Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/863703
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 3
social impact