Purpose Reliable cut-offs for basal (bCT) and calcium stimulated calcitonin (casCT) are needed for an early and accurate diagnosis of medullary thyroid cancer (MTC). Patients and methods Fifty-four new patients with nodular goiter were enrolled and analysed together with those previously published by our group for a total of 135 cases. bCT and casCT were measured by a highly sensitive method and the results compared with histological findings. In a subgroup of patients, cardiac rhythm was recorded before and during the calcium test. Results In both females (F) and males (M), there was a significant correlation between tumor size and bCT levels (P < 0.001). The receiver operating characteristic plot analyses showed that, for bCT, the new cut-off points able to separate non-MTC from MTC patients were > 30 (F) and > 34 pg/mL (M), whereas the best casCT thresholds were > 79 (F) and > 466 pg/mL (M). bCT was shown to harbour a high accuracy, though some cases were diagnosed only upon stimulation test. Importantly, combining bCT, below or above the cut-offs, with casCT above the cut-offs, all the MTC cases were correctly identified. A reversible sinus bradycardia was observed in 9% of cases during the test. Conclusions Refined cut-offs for bCT and casCT in patients with nodular goiter are reported. Sensitive bCT was shown to have a high accuracy, but the combination with casCT data was needed to identify all MTC cases. The reliability and safety of calcium test strongly favour the routine use of CT determination in nodular thyroid disease.

Basal and stimulated calcitonin for the diagnosis of medullary thyroid cancer: updated thresholds and safety assessment / Fugazzola, L.; Di Stefano, M.; Censi, S.; Repaci, A.; Colombo, C.; Grimaldi, F.; Magri, F.; Pagotto, U.; Iacobone, M.; Persani, L.; Mian, C.. - In: JOURNAL OF ENDOCRINOLOGICAL INVESTIGATION. - ISSN 1720-8386. - ELETTRONICO. - 44:3(2021), pp. 587-597. [10.1007/s40618-020-01356-9]

Basal and stimulated calcitonin for the diagnosis of medullary thyroid cancer: updated thresholds and safety assessment

Repaci, A.;Pagotto, U.;
2021

Abstract

Purpose Reliable cut-offs for basal (bCT) and calcium stimulated calcitonin (casCT) are needed for an early and accurate diagnosis of medullary thyroid cancer (MTC). Patients and methods Fifty-four new patients with nodular goiter were enrolled and analysed together with those previously published by our group for a total of 135 cases. bCT and casCT were measured by a highly sensitive method and the results compared with histological findings. In a subgroup of patients, cardiac rhythm was recorded before and during the calcium test. Results In both females (F) and males (M), there was a significant correlation between tumor size and bCT levels (P < 0.001). The receiver operating characteristic plot analyses showed that, for bCT, the new cut-off points able to separate non-MTC from MTC patients were > 30 (F) and > 34 pg/mL (M), whereas the best casCT thresholds were > 79 (F) and > 466 pg/mL (M). bCT was shown to harbour a high accuracy, though some cases were diagnosed only upon stimulation test. Importantly, combining bCT, below or above the cut-offs, with casCT above the cut-offs, all the MTC cases were correctly identified. A reversible sinus bradycardia was observed in 9% of cases during the test. Conclusions Refined cut-offs for bCT and casCT in patients with nodular goiter are reported. Sensitive bCT was shown to have a high accuracy, but the combination with casCT data was needed to identify all MTC cases. The reliability and safety of calcium test strongly favour the routine use of CT determination in nodular thyroid disease.
2021
Basal and stimulated calcitonin for the diagnosis of medullary thyroid cancer: updated thresholds and safety assessment / Fugazzola, L.; Di Stefano, M.; Censi, S.; Repaci, A.; Colombo, C.; Grimaldi, F.; Magri, F.; Pagotto, U.; Iacobone, M.; Persani, L.; Mian, C.. - In: JOURNAL OF ENDOCRINOLOGICAL INVESTIGATION. - ISSN 1720-8386. - ELETTRONICO. - 44:3(2021), pp. 587-597. [10.1007/s40618-020-01356-9]
Fugazzola, L.; Di Stefano, M.; Censi, S.; Repaci, A.; Colombo, C.; Grimaldi, F.; Magri, F.; Pagotto, U.; Iacobone, M.; Persani, L.; Mian, C.
File in questo prodotto:
File Dimensione Formato  
40618_2020_Article_1356JEI2021Pagotto&Repaci.pdf

accesso aperto

Tipo: Versione (PDF) editoriale
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 1.05 MB
Formato Adobe PDF
1.05 MB Adobe PDF Visualizza/Apri
40618_2020_1356_MOESM1_ESM.tif

accesso aperto

Tipo: File Supplementare
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 922.71 kB
Formato TIFF
922.71 kB TIFF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/860514
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 23
  • ???jsp.display-item.citation.isi??? 21
social impact