From 2020, many countries have adopted several restrictions to limit the COVID-19 pandemic. The forced containment impacted on healthcare organizations and the everyday life of patients with heart disease. We prospectively analyzed data recorded from implantable defibrillators and/or cardiac resynchronization devices of Italian patients during the lockdown (LDP), post-lockdown period (PLDP) and a control period (CP) of the previous year. We analyzed device data of the period 9 March 2019–31 May 2020 of remotely monitored patients from 34 Italian centers. Patients were also categorized according to areas with high/low infection prevalence. Among 696 patients, we observed a significant drop in median activity in LDP as compared to CP that significantly increased in the PLDP, but well below CP (all p < 0.0001). The median day heart rate and heart rate variability showed a similar trend. This behavior was associated during LDP with a significant increase in the burden of atrial arrhythmias (p = 0.0150 versus CP) and of ventricular arrhythmias [6.6 vs. 1.5 per 100 patient-weeks in CP; p = 0.0026]; the latter decreased in PLDP [0.3 per 100 patient-weeks; p = 0.0035 vs. LDP]. No modifications were recorded in thoracic fluid levels. The high/low prevalence of COVID-19 infection had no significant impact. We found an increase in the arrhythmic burden in LDP coupled with a decrease in physical activity and heart rate variability, without significant modifications of transthoracic impedance, independent from COVID-19 infection prevalence. These findings suggest a negative impact of the COVID-19 pandemic, probably related to lockdown restrictions.

Diemberger I., Vicentini A., Cattafi G., Ziacchi M., Iacopino S., Morani G., et al. (2021). The impact of covid-19 pandemic and lockdown restrictions on cardiac implantable device recipients with remote monitoring. JOURNAL OF CLINICAL MEDICINE, 10(23), 1-14 [10.3390/jcm10235626].

The impact of covid-19 pandemic and lockdown restrictions on cardiac implantable device recipients with remote monitoring

Diemberger I.;Ziacchi M.;
2021

Abstract

From 2020, many countries have adopted several restrictions to limit the COVID-19 pandemic. The forced containment impacted on healthcare organizations and the everyday life of patients with heart disease. We prospectively analyzed data recorded from implantable defibrillators and/or cardiac resynchronization devices of Italian patients during the lockdown (LDP), post-lockdown period (PLDP) and a control period (CP) of the previous year. We analyzed device data of the period 9 March 2019–31 May 2020 of remotely monitored patients from 34 Italian centers. Patients were also categorized according to areas with high/low infection prevalence. Among 696 patients, we observed a significant drop in median activity in LDP as compared to CP that significantly increased in the PLDP, but well below CP (all p < 0.0001). The median day heart rate and heart rate variability showed a similar trend. This behavior was associated during LDP with a significant increase in the burden of atrial arrhythmias (p = 0.0150 versus CP) and of ventricular arrhythmias [6.6 vs. 1.5 per 100 patient-weeks in CP; p = 0.0026]; the latter decreased in PLDP [0.3 per 100 patient-weeks; p = 0.0035 vs. LDP]. No modifications were recorded in thoracic fluid levels. The high/low prevalence of COVID-19 infection had no significant impact. We found an increase in the arrhythmic burden in LDP coupled with a decrease in physical activity and heart rate variability, without significant modifications of transthoracic impedance, independent from COVID-19 infection prevalence. These findings suggest a negative impact of the COVID-19 pandemic, probably related to lockdown restrictions.
2021
Diemberger I., Vicentini A., Cattafi G., Ziacchi M., Iacopino S., Morani G., et al. (2021). The impact of covid-19 pandemic and lockdown restrictions on cardiac implantable device recipients with remote monitoring. JOURNAL OF CLINICAL MEDICINE, 10(23), 1-14 [10.3390/jcm10235626].
Diemberger I.; Vicentini A.; Cattafi G.; Ziacchi M.; Iacopino S.; Morani G.; Pisano E.; Molon G.; Giovannini T.; Russo A.D.; Boriani G.; Bertaglia E.;...espandi
File in questo prodotto:
File Dimensione Formato  
jcm-10-05626.pdf

accesso aperto

Tipo: Versione (PDF) editoriale / Version Of Record
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 9.97 MB
Formato Adobe PDF
9.97 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/859804
Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 10
social impact