Recently, the progress in techniques and in projecting new prosthetic designs has allowed increasing indications for total ankle replacement (TAR) as treatment for ankle osteoarthritis. This retrospective work comprehended 39 subjects aged between 47 and 79 years old. The patients, observed for at least 12 months (mean follow up of 18.2 ± 4.1 months), have been evaluated according to clinical and radiological parameters, both pre-and post-operatively. The AOFAS and VAS score significantly improved, respectively, from 46.2 ± 4.8 to 93.9 ± 4.1 and from 7.1 ± 1.1 to 0.7 ± 0.5 (p value < 0.05). At the final evaluation, the mean plantarflexion passed from 12.2◦ ± 2.3◦ to 18.1◦ ± 2.4◦ (p value < 0.05) and dorsiflexion from a pre-operative mean value of 8.7◦ ± 4.1◦ to 21.7◦ ± 5.4◦ post-operatively (p value < 0.05). This study found that this new total ankle replacement design is a safe and effective procedure for patients effected by end-stage ankle osteoarthritis. Improvements have been demonstrated in terms of range of motion, radiographic parameters and patient-reported outcomes. However, further studies are needed to assess the long-term performance of these prostheses.

Mosca M., Caravelli S., Vocale E., Massimi S., Censoni D., Di Ponte M., et al. (2021). Clinical radiographical outcomes and complications after a brand-new total ankle replacement design through an anterior approach: A retrospective at a short-term follow up. JOURNAL OF CLINICAL MEDICINE, 10(11), 2258-2264 [10.3390/jcm10112258].

Clinical radiographical outcomes and complications after a brand-new total ankle replacement design through an anterior approach: A retrospective at a short-term follow up

Mosca M.;Caravelli S.;Vocale E.;Massimi S.;Censoni D.;Di Ponte M.;Fuiano M.;Zaffagnini S.
2021

Abstract

Recently, the progress in techniques and in projecting new prosthetic designs has allowed increasing indications for total ankle replacement (TAR) as treatment for ankle osteoarthritis. This retrospective work comprehended 39 subjects aged between 47 and 79 years old. The patients, observed for at least 12 months (mean follow up of 18.2 ± 4.1 months), have been evaluated according to clinical and radiological parameters, both pre-and post-operatively. The AOFAS and VAS score significantly improved, respectively, from 46.2 ± 4.8 to 93.9 ± 4.1 and from 7.1 ± 1.1 to 0.7 ± 0.5 (p value < 0.05). At the final evaluation, the mean plantarflexion passed from 12.2◦ ± 2.3◦ to 18.1◦ ± 2.4◦ (p value < 0.05) and dorsiflexion from a pre-operative mean value of 8.7◦ ± 4.1◦ to 21.7◦ ± 5.4◦ post-operatively (p value < 0.05). This study found that this new total ankle replacement design is a safe and effective procedure for patients effected by end-stage ankle osteoarthritis. Improvements have been demonstrated in terms of range of motion, radiographic parameters and patient-reported outcomes. However, further studies are needed to assess the long-term performance of these prostheses.
2021
Mosca M., Caravelli S., Vocale E., Massimi S., Censoni D., Di Ponte M., et al. (2021). Clinical radiographical outcomes and complications after a brand-new total ankle replacement design through an anterior approach: A retrospective at a short-term follow up. JOURNAL OF CLINICAL MEDICINE, 10(11), 2258-2264 [10.3390/jcm10112258].
Mosca M.; Caravelli S.; Vocale E.; Massimi S.; Censoni D.; Di Ponte M.; Fuiano M.; Zaffagnini S.
File in questo prodotto:
File Dimensione Formato  
jcm-10-02258.pdf

accesso aperto

Tipo: Versione (PDF) editoriale
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 1.21 MB
Formato Adobe PDF
1.21 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/858239
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 7
social impact