Purposes: this clinical study evaluated the accuracy and execution time of a digital imaging fiber-optic transillumination (DIFOTI) technique for the detection of approximal caries in posterior teeth compared to intra-oral examination associated with bitewing radiographs. Methods: one hundred patients were selected and submitted to clinical inspection and bitewing radiographs. The outcomes of this process were converted into scores, according to the International Caries Detection and Assessment System (ICDAS): 0—sound tooth; 1, 2, and 3—carious lesion confined within enamel; 4, 5, and 6—dentin carious lesion. Subsequently, an independent investigator acquired digital images of the same teeth using a DIFOTI device (DIAGNOcam, Kavo Dental), which were also converted into ICDAS scores. The time required for executing diagnostic procedures was measured. The clinical sensitivity and specificity of DIFOTI were analyzed by receiver operating characteristic (ROC) curves. The time necessary to perform the diagnostic methods was evaluated by Mann–Whit-ney U (alfa = 0.05). Results: the overall test accuracy for the DIFOTI-based device ranged from 0.717 to 0.815 (area under the ROC curve) with p < 0.0001 for all ICDAS scores. Bitewing radiographs took almost twice the time required by DIFOTI (p < 0.001). Conclusions: the DIFOTI-based device DI-AGNOcam provided accurate detection of approximal caries in posterior teeth, even at early stages. The technique employed for transillumination caries diagnosis by the same device took less time than conventional bitewing radiographs. Clinical Relevance: transillumination devices, such as DI-AGNOcam, can be accurately used for caries diagnosis in approximal surfaces of posterior teeth, demanding less clinical time and without radiation-related risks.

Clinical analysis of the diagnostic accuracy and time of execution of a transillumination caries detection method compared to bitewing radiographs / Pelliccioni G.A.; Gatto M.R.A.; Bolognesi S.; Dal Fiume D.; Sebold M.; Breschi L.. - In: JOURNAL OF CLINICAL MEDICINE. - ISSN 2077-0383. - ELETTRONICO. - 10:20(2021), pp. 4780.4780-4780.4789. [10.3390/jcm10204780]

Clinical analysis of the diagnostic accuracy and time of execution of a transillumination caries detection method compared to bitewing radiographs

Pelliccioni G. A.
Primo
Conceptualization
;
Gatto M. R. A.
Secondo
Formal Analysis
;
Breschi L.
Ultimo
Membro del Collaboration Group
2021

Abstract

Purposes: this clinical study evaluated the accuracy and execution time of a digital imaging fiber-optic transillumination (DIFOTI) technique for the detection of approximal caries in posterior teeth compared to intra-oral examination associated with bitewing radiographs. Methods: one hundred patients were selected and submitted to clinical inspection and bitewing radiographs. The outcomes of this process were converted into scores, according to the International Caries Detection and Assessment System (ICDAS): 0—sound tooth; 1, 2, and 3—carious lesion confined within enamel; 4, 5, and 6—dentin carious lesion. Subsequently, an independent investigator acquired digital images of the same teeth using a DIFOTI device (DIAGNOcam, Kavo Dental), which were also converted into ICDAS scores. The time required for executing diagnostic procedures was measured. The clinical sensitivity and specificity of DIFOTI were analyzed by receiver operating characteristic (ROC) curves. The time necessary to perform the diagnostic methods was evaluated by Mann–Whit-ney U (alfa = 0.05). Results: the overall test accuracy for the DIFOTI-based device ranged from 0.717 to 0.815 (area under the ROC curve) with p < 0.0001 for all ICDAS scores. Bitewing radiographs took almost twice the time required by DIFOTI (p < 0.001). Conclusions: the DIFOTI-based device DI-AGNOcam provided accurate detection of approximal caries in posterior teeth, even at early stages. The technique employed for transillumination caries diagnosis by the same device took less time than conventional bitewing radiographs. Clinical Relevance: transillumination devices, such as DI-AGNOcam, can be accurately used for caries diagnosis in approximal surfaces of posterior teeth, demanding less clinical time and without radiation-related risks.
2021
Clinical analysis of the diagnostic accuracy and time of execution of a transillumination caries detection method compared to bitewing radiographs / Pelliccioni G.A.; Gatto M.R.A.; Bolognesi S.; Dal Fiume D.; Sebold M.; Breschi L.. - In: JOURNAL OF CLINICAL MEDICINE. - ISSN 2077-0383. - ELETTRONICO. - 10:20(2021), pp. 4780.4780-4780.4789. [10.3390/jcm10204780]
Pelliccioni G.A.; Gatto M.R.A.; Bolognesi S.; Dal Fiume D.; Sebold M.; Breschi L.
File in questo prodotto:
File Dimensione Formato  
Pell et al DIFOTI.pdf

accesso aperto

Tipo: Versione (PDF) editoriale
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 534.38 kB
Formato Adobe PDF
534.38 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/855175
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact