Proponents of a telemetrically adjustable pulmonary artery band (PAB) device have cited simplified postoperative management and shortened length of stay as advantages associated with that technology. This report concerns a recent experience with both conventional pulmonary artery banding (conv-PAB) and the telemetrically adjustable PAB FloWatch (FW-PAB). From January 2005 through December 2008, 19 consecutive infants underwent either conv-PAB (8 patients, mean age 3.5 months, mean weight 4.1 kg) or FW-PAB (11 patients, mean age 2.6 months, mean weight 3.1 kg). Indications for PAB were left ventricular retraining (1 patient in FW-PAB), palliation prior to biventricular repair (7 patients in conv-PAB and 10 in FW-PAB group), and staged univentricular repair (1 patient in conv-PAB). In-hospital mortality was 0%. In the FW-PAB group, 1 FloWatch device was removed because of hemodynamic compromise related to the bulk of the device. There were no major complications in the conv-PAB group and no differences between groups with respect to postoperative ventilation time or length of stay in the intensive care unit or in hospital. In the FW-PAB group, a mean of 3.1 ± 1.7 regulations per patient were undertaken. Of the regulations, 85% (29/34) were adjustments to tighten the device, and 15% (5/34) were to loosen it. During follow-up, 8 patients underwent intracardiac repair and pulmonary artery debanding: 4 in the conv-PAB group and 4 in the FW-PAB group. The course of patients in both groups after PAB were similar. Major differences in length of stay and resource utilization were not apparent. © 2010, SAGE Publications. All rights reserved.

Pulmonary Artery Banding: When Is the Use of a Telemetrically Adjustable Device Indicated? / D'alfonso A.; Quarti A.; Colaneri M.; Baldinelli A.; Pozzi M.. - In: WORLD JOURNAL FOR PEDIATRIC & CONGENITAL HEART SURGERY. - ISSN 2150-1351. - STAMPA. - 1:2(2010), pp. 232-239. [10.1177/2150135110371135]

Pulmonary Artery Banding: When Is the Use of a Telemetrically Adjustable Device Indicated?

Quarti A.
Secondo
Conceptualization
;
2010

Abstract

Proponents of a telemetrically adjustable pulmonary artery band (PAB) device have cited simplified postoperative management and shortened length of stay as advantages associated with that technology. This report concerns a recent experience with both conventional pulmonary artery banding (conv-PAB) and the telemetrically adjustable PAB FloWatch (FW-PAB). From January 2005 through December 2008, 19 consecutive infants underwent either conv-PAB (8 patients, mean age 3.5 months, mean weight 4.1 kg) or FW-PAB (11 patients, mean age 2.6 months, mean weight 3.1 kg). Indications for PAB were left ventricular retraining (1 patient in FW-PAB), palliation prior to biventricular repair (7 patients in conv-PAB and 10 in FW-PAB group), and staged univentricular repair (1 patient in conv-PAB). In-hospital mortality was 0%. In the FW-PAB group, 1 FloWatch device was removed because of hemodynamic compromise related to the bulk of the device. There were no major complications in the conv-PAB group and no differences between groups with respect to postoperative ventilation time or length of stay in the intensive care unit or in hospital. In the FW-PAB group, a mean of 3.1 ± 1.7 regulations per patient were undertaken. Of the regulations, 85% (29/34) were adjustments to tighten the device, and 15% (5/34) were to loosen it. During follow-up, 8 patients underwent intracardiac repair and pulmonary artery debanding: 4 in the conv-PAB group and 4 in the FW-PAB group. The course of patients in both groups after PAB were similar. Major differences in length of stay and resource utilization were not apparent. © 2010, SAGE Publications. All rights reserved.
2010
Pulmonary Artery Banding: When Is the Use of a Telemetrically Adjustable Device Indicated? / D'alfonso A.; Quarti A.; Colaneri M.; Baldinelli A.; Pozzi M.. - In: WORLD JOURNAL FOR PEDIATRIC & CONGENITAL HEART SURGERY. - ISSN 2150-1351. - STAMPA. - 1:2(2010), pp. 232-239. [10.1177/2150135110371135]
D'alfonso A.; Quarti A.; Colaneri M.; Baldinelli A.; Pozzi M.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/850414
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? ND
social impact