Wildfires approaching the Wildland-Industrial Interfaces can be a serious threat for industrial items located at the plant boundary. These items are typically storage tanks involving large amounts of hazardous substances. Ensuring their integrity is of paramount importance to prevent the wildfire spread inside the industrial plant, avoiding the occurrence of major accidents such as fires, explosions and toxic releases. A methodology for the evaluation of safety distances between tanks and vegetation for the protection from wildfire hazard was developed and applied to a case study. The outcomes provide useful information for an effective emergency response planning in the case of wildfire. Moreover, the results obtained rise concern about the appropriateness of clearance areas between the vegetation and industrial areas currently adopted.

Ricci F., Scarponi G.E., Pastor E., Munoz J.A., Planas E., Cozzani V. (2021). Vulnerability of industrial storage tanks to wildfire: A case study. CHEMICAL ENGINEERING TRANSACTIONS, 86, 235-240 [10.3303/CET2186040].

Vulnerability of industrial storage tanks to wildfire: A case study

Ricci F.
Primo
;
Scarponi G. E.
Secondo
;
Cozzani V.
Ultimo
2021

Abstract

Wildfires approaching the Wildland-Industrial Interfaces can be a serious threat for industrial items located at the plant boundary. These items are typically storage tanks involving large amounts of hazardous substances. Ensuring their integrity is of paramount importance to prevent the wildfire spread inside the industrial plant, avoiding the occurrence of major accidents such as fires, explosions and toxic releases. A methodology for the evaluation of safety distances between tanks and vegetation for the protection from wildfire hazard was developed and applied to a case study. The outcomes provide useful information for an effective emergency response planning in the case of wildfire. Moreover, the results obtained rise concern about the appropriateness of clearance areas between the vegetation and industrial areas currently adopted.
2021
Ricci F., Scarponi G.E., Pastor E., Munoz J.A., Planas E., Cozzani V. (2021). Vulnerability of industrial storage tanks to wildfire: A case study. CHEMICAL ENGINEERING TRANSACTIONS, 86, 235-240 [10.3303/CET2186040].
Ricci F.; Scarponi G.E.; Pastor E.; Munoz J.A.; Planas E.; Cozzani V.
File in questo prodotto:
File Dimensione Formato  
EDIT Vulnerability of Industrial Storage.pdf

accesso aperto

Tipo: Versione (PDF) editoriale
Licenza: Licenza per accesso libero gratuito
Dimensione 1.08 MB
Formato Adobe PDF
1.08 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/849298
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? ND
social impact