Power quality evaluation is the process of assessing the actual power network parameters with respect to the ideal conditions. However, several new assets and devices among the grid include mining the voltage and current quality. For example, the power converters needed for renewable energy sources’ connection to the grid, electric vehicles, etc., are some of the main sources of disturbances that inject high-frequency components into the grid. Consequently, instrument transformers (ITs) should be capable of measuring distorted currents and voltages with the same level of accuracy guaranteed for the ideal frequency (50-60 Hz). This is not a simple task if one considers that several other influence quantities endlessly act on the ITs. To this purpose, considering the lack of a standard, this work presents a measurement setup and specific tests for testing a commonly used type of low-power current transformer, the Rogowski coil (RC). In particular, the accuracy performance (ratio error and phase displacement) of the RCs was evaluated when measuring distorted signals while other influence quantities affected the RCs. Such quantities included positioning, burden, and magnetic field. The results indicate which quantities (or combination of them) have the greatest effect on the RC’s accuracy performance.

Effect of Proximity, Burden, and Position on the Power Quality Accuracy Performance of Rogowski Coils / Mingotti A.; Costa F.; Peretto L.; Tinarelli R.. - In: SENSORS. - ISSN 1424-8220. - ELETTRONICO. - 22:1(2022), pp. 397.1-397.19. [10.3390/s22010397]

Effect of Proximity, Burden, and Position on the Power Quality Accuracy Performance of Rogowski Coils

Mingotti A.
Primo
;
Costa F.
Secondo
;
Peretto L.
Penultimo
;
Tinarelli R.
Ultimo
2022

Abstract

Power quality evaluation is the process of assessing the actual power network parameters with respect to the ideal conditions. However, several new assets and devices among the grid include mining the voltage and current quality. For example, the power converters needed for renewable energy sources’ connection to the grid, electric vehicles, etc., are some of the main sources of disturbances that inject high-frequency components into the grid. Consequently, instrument transformers (ITs) should be capable of measuring distorted currents and voltages with the same level of accuracy guaranteed for the ideal frequency (50-60 Hz). This is not a simple task if one considers that several other influence quantities endlessly act on the ITs. To this purpose, considering the lack of a standard, this work presents a measurement setup and specific tests for testing a commonly used type of low-power current transformer, the Rogowski coil (RC). In particular, the accuracy performance (ratio error and phase displacement) of the RCs was evaluated when measuring distorted signals while other influence quantities affected the RCs. Such quantities included positioning, burden, and magnetic field. The results indicate which quantities (or combination of them) have the greatest effect on the RC’s accuracy performance.
2022
Effect of Proximity, Burden, and Position on the Power Quality Accuracy Performance of Rogowski Coils / Mingotti A.; Costa F.; Peretto L.; Tinarelli R.. - In: SENSORS. - ISSN 1424-8220. - ELETTRONICO. - 22:1(2022), pp. 397.1-397.19. [10.3390/s22010397]
Mingotti A.; Costa F.; Peretto L.; Tinarelli R.
File in questo prodotto:
File Dimensione Formato  
sensors-22-00397-v2.pdf

accesso aperto

Tipo: Versione (PDF) editoriale
Licenza: Creative commons
Dimensione 6.99 MB
Formato Adobe PDF
6.99 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/845454
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 4
social impact