During the autumn of 2006 a final test of a sample of double-stack MRPC (Multigap Resistive Plate Chamber) strips, randomly chosen from two years of mass production (the ALICE Time-Of-Flight detector is made of 1638 strips), was carried out at the CERN Proton Synchrotron facility. The results on the performances of the MRPCs and of the front-end and readout electronics will be presented. It is confirmed that these devices have a very good uniformity of response, a long streamer-free plateau, an efficiency higher than 99% and an “intrinsic” time resolution better than about 40 ps.
A. Akindinov, A. Alici, P. Antonioli, S. Arcelli, Y.W. Baek, M. Basile, et al. (2009). Final test of the MRPC production for the ALICE TOF detector. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 602(3), 709-712 [10.1016/j.nima.2008.12.095].
Final test of the MRPC production for the ALICE TOF detector.
ALICI, ANDREA;ARCELLI, SILVIA;BASILE, MAURIZIO;CIFARELLI, LUISA;SCIOLI, GILDA;SILENZI, ALESSANDRO;
2009
Abstract
During the autumn of 2006 a final test of a sample of double-stack MRPC (Multigap Resistive Plate Chamber) strips, randomly chosen from two years of mass production (the ALICE Time-Of-Flight detector is made of 1638 strips), was carried out at the CERN Proton Synchrotron facility. The results on the performances of the MRPCs and of the front-end and readout electronics will be presented. It is confirmed that these devices have a very good uniformity of response, a long streamer-free plateau, an efficiency higher than 99% and an “intrinsic” time resolution better than about 40 ps.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.