All the steps which led to the construction of the ALICE-TOF detector were strictly followed by a set of quality assurance procedures to guarantee high and uniform performances. Once a module of the detector (whose basic element is the Multigap Resistive Plate Chamber) is assembled, a final test concerning the data readout applies. While the detector is taking data, both during test and physics runs, a check of the quality of the data is needed. For this purpose some monitoring tools have been developed. These tools have been used since the beginning of the TOF commissioning and finally they have also been successfully used during the first global data-taking test-runs of ALICE.

A. Akindinov, A. Alici, P. Antonioli, S. Arcelli, Y.W. Baek, M. Basile, et al. (2009). Data quality monitor as the final quality assurance procedure for the ALICE-TOF detector. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 602(3), 821-824 [10.1016/j.nima.2008.12.138].

Data quality monitor as the final quality assurance procedure for the ALICE-TOF detector.

ALICI, ANDREA;ARCELLI, SILVIA;BASILE, MAURIZIO;CIFARELLI, LUISA;SCIOLI, GILDA;SILENZI, ALESSANDRO;
2009

Abstract

All the steps which led to the construction of the ALICE-TOF detector were strictly followed by a set of quality assurance procedures to guarantee high and uniform performances. Once a module of the detector (whose basic element is the Multigap Resistive Plate Chamber) is assembled, a final test concerning the data readout applies. While the detector is taking data, both during test and physics runs, a check of the quality of the data is needed. For this purpose some monitoring tools have been developed. These tools have been used since the beginning of the TOF commissioning and finally they have also been successfully used during the first global data-taking test-runs of ALICE.
2009
A. Akindinov, A. Alici, P. Antonioli, S. Arcelli, Y.W. Baek, M. Basile, et al. (2009). Data quality monitor as the final quality assurance procedure for the ALICE-TOF detector. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 602(3), 821-824 [10.1016/j.nima.2008.12.138].
A. Akindinov; A. Alici; P. Antonioli; S. Arcelli; Y.W. Baek; M. Basile; G. Cara Romeo; L. Cifarelli; F. Cindolo; A. De Caro; D. De Gruttola; S. De Pas...espandi
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/83431
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact