This paper has the purpose to investigate the variation of electric field inside a HVDC cable insulation, and consequent potentiality of partial discharge inception in a defect upon load current variation. Simulations carried out by COMSOL Multiphysics show that load variations can incept partial discharges during cable operation at a constant voltage, depending on insulating material characteristics, defect size and location, and, in particular, the temperature and field dependence of electrical conductivity. Different values for temperature and field dependency of electrical conductivity, as well as of thermal conductivity and heat capacity are considered and their effect on the field distribution inside cavities near inner and outer semiconducting layer analyzed. For this purpose, a new analytical model to predict the behavior of PD amplitude and repetition rate from cable energization to steady state, including load variation, is introduced. The likelihood of PD inception during load transients, and not only voltage transients as previously demonstrated, poses further attention and constraints to HVDC cable design.

Investigating conditions for an unexpected additional source of partial discharges in DC cables: load power variations / Hadi Naderiallaf, Paolo Seri, Gian Carlo Montanari. - In: IEEE TRANSACTIONS ON POWER DELIVERY. - ISSN 0885-8977. - ELETTRONICO. - 36:5(2021), pp. 3082-3090. [10.1109/TPWRD.2020.3032800]

Investigating conditions for an unexpected additional source of partial discharges in DC cables: load power variations.

Hadi Naderiallaf
;
Paolo Seri;Gian Carlo Montanari
2021

Abstract

This paper has the purpose to investigate the variation of electric field inside a HVDC cable insulation, and consequent potentiality of partial discharge inception in a defect upon load current variation. Simulations carried out by COMSOL Multiphysics show that load variations can incept partial discharges during cable operation at a constant voltage, depending on insulating material characteristics, defect size and location, and, in particular, the temperature and field dependence of electrical conductivity. Different values for temperature and field dependency of electrical conductivity, as well as of thermal conductivity and heat capacity are considered and their effect on the field distribution inside cavities near inner and outer semiconducting layer analyzed. For this purpose, a new analytical model to predict the behavior of PD amplitude and repetition rate from cable energization to steady state, including load variation, is introduced. The likelihood of PD inception during load transients, and not only voltage transients as previously demonstrated, poses further attention and constraints to HVDC cable design.
2021
Investigating conditions for an unexpected additional source of partial discharges in DC cables: load power variations / Hadi Naderiallaf, Paolo Seri, Gian Carlo Montanari. - In: IEEE TRANSACTIONS ON POWER DELIVERY. - ISSN 0885-8977. - ELETTRONICO. - 36:5(2021), pp. 3082-3090. [10.1109/TPWRD.2020.3032800]
Hadi Naderiallaf, Paolo Seri, Gian Carlo Montanari
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/831377
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 9
social impact