As drugs can be multichannel blockers it is important to assess their cardiac safety taking into account multiple currents. In silico action potential (AP) models have been proposed for being able to integrate drugs effect on ionic currents and generate the resulting AP. However, a mathematical description of drug effects is required, which could be inaccurate. Dynamic Clamp has been proposed for drug cardiac safety assessment. In the dynamic action potential clamp (dAPC) configuration it creates an hybrid model connecting a real cell with a computer simulation. This way, drugs could be administrated directly to real cells, and effects on currents can be taken into account when generating the AP. Here we design and simulate a parallel multichannel dAPC system. The system includes the real cells overexpressing the currents of interest, the voltage clamp acquisition system, and the AP in silico model.

Development, Implementation and Testing of a Multicellular Dynamic Action Potential Clamp Simulator for Drug Cardiac Safety Assessment / Camporesi M.; Bartolucci C.; Lei C.L.; Mirams G.R.; De Boer T.P.; Severi S.. - In: COMPUTING IN CARDIOLOGY. - ISSN 2325-8861. - ELETTRONICO. - 2020-:(2020), pp. 9344189.1-9344189.4. (Intervento presentato al convegno 2020 Computing in Cardiology, CinC 2020 tenutosi a ita nel 2020) [10.22489/CinC.2020.416].

Development, Implementation and Testing of a Multicellular Dynamic Action Potential Clamp Simulator for Drug Cardiac Safety Assessment

Camporesi M.;Bartolucci C.;Severi S.
2020

Abstract

As drugs can be multichannel blockers it is important to assess their cardiac safety taking into account multiple currents. In silico action potential (AP) models have been proposed for being able to integrate drugs effect on ionic currents and generate the resulting AP. However, a mathematical description of drug effects is required, which could be inaccurate. Dynamic Clamp has been proposed for drug cardiac safety assessment. In the dynamic action potential clamp (dAPC) configuration it creates an hybrid model connecting a real cell with a computer simulation. This way, drugs could be administrated directly to real cells, and effects on currents can be taken into account when generating the AP. Here we design and simulate a parallel multichannel dAPC system. The system includes the real cells overexpressing the currents of interest, the voltage clamp acquisition system, and the AP in silico model.
2020
Computing in Cardiology
1
4
Development, Implementation and Testing of a Multicellular Dynamic Action Potential Clamp Simulator for Drug Cardiac Safety Assessment / Camporesi M.; Bartolucci C.; Lei C.L.; Mirams G.R.; De Boer T.P.; Severi S.. - In: COMPUTING IN CARDIOLOGY. - ISSN 2325-8861. - ELETTRONICO. - 2020-:(2020), pp. 9344189.1-9344189.4. (Intervento presentato al convegno 2020 Computing in Cardiology, CinC 2020 tenutosi a ita nel 2020) [10.22489/CinC.2020.416].
Camporesi M.; Bartolucci C.; Lei C.L.; Mirams G.R.; De Boer T.P.; Severi S.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/821432
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact