In this paper, the impact of control on faulted induction machine behavior is presented. The diagnostic indexes usually used for open-loop operation are no longer effective. Simulation and experimental results show that the spectrum of the field current component id in a field-oriented controlled machine has suitable features that can lead to an effective diagnostic procedure. Specifically, in the case of stator and rotor faults the id spectrum components at frequencies 2fand 2sf, respectively, are quite independent of control parameters and dependent on the fault extent. © 2000 IEEE.
Bellini A., Filippetti F., Franceschini G., Tassoni C. (2000). Closed-loop control impact on the diagnosis of induction motors faults. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 36(5), 1318-1339 [10.1109/28.871280].
Closed-loop control impact on the diagnosis of induction motors faults
Bellini A.
;Filippetti F.;Tassoni C.
2000
Abstract
In this paper, the impact of control on faulted induction machine behavior is presented. The diagnostic indexes usually used for open-loop operation are no longer effective. Simulation and experimental results show that the spectrum of the field current component id in a field-oriented controlled machine has suitable features that can lead to an effective diagnostic procedure. Specifically, in the case of stator and rotor faults the id spectrum components at frequencies 2fand 2sf, respectively, are quite independent of control parameters and dependent on the fault extent. © 2000 IEEE.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.