The interest in multi-storey CLT buildings in seismic areas is leading to the development of new strategies to increase the lateral stiffness of shear walls and to resist high tensile forces due to rocking. Both these purposes can be achieved with vertical steel ties placed at each shear-wall end, to directly transfer tensile forces from each storey to the foundation. Three technologies are proposed for transferring forces from CLT panels to the ties: the use of nailed plates, of screwed connectors, or directly by contact with a thick plate at the top of each storey wall. The dynamic behaviour of CLT shear walls, representing the bracing system of a building and anchored with the aforementioned technologies, has been investigated by means of dynamic analyses and a comparison with the use of common nailed plates or screwed connections without ties. Results, varying the number of storeys and the seismic mass, show that the proposed technology is an effective strategy to increase the feasibility of multi-storey CLT buildings. Complementary non-linear static analyses have been performed to evaluate the actual displacement capacity and ductility of the systems.

Stefano Pacchioli, Luca Pozza, Davide Trutalli, Andrea Polastri (2021). Earthquake-resistant CLT buildings stiffened with vertical steel ties. JOURNAL OF BUILDING ENGINEERING, 40, Pages 102334, 1-11 [10.1016/j.jobe.2021.102334].

Earthquake-resistant CLT buildings stiffened with vertical steel ties

Stefano Pacchioli
Primo
;
Luca Pozza
Secondo
;
2021

Abstract

The interest in multi-storey CLT buildings in seismic areas is leading to the development of new strategies to increase the lateral stiffness of shear walls and to resist high tensile forces due to rocking. Both these purposes can be achieved with vertical steel ties placed at each shear-wall end, to directly transfer tensile forces from each storey to the foundation. Three technologies are proposed for transferring forces from CLT panels to the ties: the use of nailed plates, of screwed connectors, or directly by contact with a thick plate at the top of each storey wall. The dynamic behaviour of CLT shear walls, representing the bracing system of a building and anchored with the aforementioned technologies, has been investigated by means of dynamic analyses and a comparison with the use of common nailed plates or screwed connections without ties. Results, varying the number of storeys and the seismic mass, show that the proposed technology is an effective strategy to increase the feasibility of multi-storey CLT buildings. Complementary non-linear static analyses have been performed to evaluate the actual displacement capacity and ductility of the systems.
2021
Stefano Pacchioli, Luca Pozza, Davide Trutalli, Andrea Polastri (2021). Earthquake-resistant CLT buildings stiffened with vertical steel ties. JOURNAL OF BUILDING ENGINEERING, 40, Pages 102334, 1-11 [10.1016/j.jobe.2021.102334].
Stefano Pacchioli; Luca Pozza; Davide Trutalli; Andrea Polastri
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/817351
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 5
social impact