Purpose: The main purpose and research question of the study are to compare the efficacy of high-security closed versus open devices for human oocytes’ vitrification. Methods: A prospective randomized study was conducted. A total of 737 patients attending the Infertility and IVF Unit at S.Orsola University Hospital (Italy) between October 2015 and April 2020 were randomly assigned to two groups. A total of 368 patients were assigned to group 1 (High-Security Vitrification™ - HSV) and 369 to group 2 (Cryotop® open system). Oocyte survival, fertilization, cleavage, pregnancy, implantation, and miscarriage rate were compared between the two groups. Results: No statistically significant differences were observed on survival rate (70.3% vs. 73.3%), fertilization rate (70.8% vs. 74.9%), cleavage rate (90.6% vs. 90.3%), pregnancy/transfer ratio (32.0% vs. 31.8%), implantation rate (19.7% vs. 19.9%), nor miscarriage rates (22.1% vs. 21.5%) between the two groups. Women’s mean age in group 1 (36.18 ± 3.92) and group 2 (35.88 ± 3.88) was not significantly different (P =.297). A total of 4029 oocytes were vitrified (1980 and 2049 in groups 1 and 2 respectively). A total of 2564 were warmed (1469 and 1095 in groups 1 and 2 respectively). A total of 1386 morphologically eligible oocytes were inseminated by intracytoplasmic sperm injection (792 and 594 respectively, P =.304). Conclusions: The present study shows that the replacement of the open vitrification system by a closed one has no impact on in vitro and in vivo survival, development, pregnancy and implantation rate. Furthermore, to ensure safety, especially during the current COVID-19 pandemic, the use of the closed device eliminates the potential samples’ contamination during vitrification and storage.

Porcu E., Tranquillo M.L., Notarangelo L., Ciotti P.M., Calza N., Zuffa S., et al. (2021). High-security closed devices are efficient and safe to protect human oocytes from potential risk of viral contamination during vitrification and storage especially in the COVID-19 pandemic. JOURNAL OF ASSISTED REPRODUCTION AND GENETICS, 38(3), 681-688 [10.1007/s10815-021-02062-y].

High-security closed devices are efficient and safe to protect human oocytes from potential risk of viral contamination during vitrification and storage especially in the COVID-19 pandemic

Porcu E.
Primo
;
Notarangelo L.;Ciotti P. M.;Nardi E.;Dirodi M.;Cipriani L.;Labriola F. S.;Damiano G.
2021

Abstract

Purpose: The main purpose and research question of the study are to compare the efficacy of high-security closed versus open devices for human oocytes’ vitrification. Methods: A prospective randomized study was conducted. A total of 737 patients attending the Infertility and IVF Unit at S.Orsola University Hospital (Italy) between October 2015 and April 2020 were randomly assigned to two groups. A total of 368 patients were assigned to group 1 (High-Security Vitrification™ - HSV) and 369 to group 2 (Cryotop® open system). Oocyte survival, fertilization, cleavage, pregnancy, implantation, and miscarriage rate were compared between the two groups. Results: No statistically significant differences were observed on survival rate (70.3% vs. 73.3%), fertilization rate (70.8% vs. 74.9%), cleavage rate (90.6% vs. 90.3%), pregnancy/transfer ratio (32.0% vs. 31.8%), implantation rate (19.7% vs. 19.9%), nor miscarriage rates (22.1% vs. 21.5%) between the two groups. Women’s mean age in group 1 (36.18 ± 3.92) and group 2 (35.88 ± 3.88) was not significantly different (P =.297). A total of 4029 oocytes were vitrified (1980 and 2049 in groups 1 and 2 respectively). A total of 2564 were warmed (1469 and 1095 in groups 1 and 2 respectively). A total of 1386 morphologically eligible oocytes were inseminated by intracytoplasmic sperm injection (792 and 594 respectively, P =.304). Conclusions: The present study shows that the replacement of the open vitrification system by a closed one has no impact on in vitro and in vivo survival, development, pregnancy and implantation rate. Furthermore, to ensure safety, especially during the current COVID-19 pandemic, the use of the closed device eliminates the potential samples’ contamination during vitrification and storage.
2021
Porcu E., Tranquillo M.L., Notarangelo L., Ciotti P.M., Calza N., Zuffa S., et al. (2021). High-security closed devices are efficient and safe to protect human oocytes from potential risk of viral contamination during vitrification and storage especially in the COVID-19 pandemic. JOURNAL OF ASSISTED REPRODUCTION AND GENETICS, 38(3), 681-688 [10.1007/s10815-021-02062-y].
Porcu E.; Tranquillo M.L.; Notarangelo L.; Ciotti P.M.; Calza N.; Zuffa S.; Mori L.; Nardi E.; Dirodi M.; Cipriani L.; Labriola F.S.; Damiano G....espandi
File in questo prodotto:
File Dimensione Formato  
Porcu2021_Article_High-securityClosedDevicesAreE(1).pdf

accesso aperto

Tipo: Versione (PDF) editoriale
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 290.06 kB
Formato Adobe PDF
290.06 kB Adobe PDF Visualizza/Apri