In September 2008 the Slim5 collaboration submitted a low material budget silicon demonstrator to test with protons at the PS beam at CERN. The beam test setup was composed of a four double sided microstrip reference telescope and different detectors (DUTs) placed inside: a 4k-Pixel Matrix of Deep N Well MAPS, developed in a 130 nm CMOS Technology and a high resistivity double sided silicon detector, with short strips at 45ring operator angle to the detectors edge, read out by the FSSR2 chip. All the systems were self-triggered and read out by a fast DAQ system. The beam test setup as the data acquisition and the trigger system are explained and the data acquisition performances are shown.

L. Fabbri, M. Bruschi, R. Di Sipio, B. Giacobbe, A. Gabrielli, F. Giorgi, et al. (2010). The high rate data acquisition system for the SLIM5 beam test. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 617, 321-323 [10.1016/j.nima.2009.10.045].

The high rate data acquisition system for the SLIM5 beam test

FABBRI, LAURA;DI SIPIO, RICCARDO;GABRIELLI, ALESSANDRO;GIORGI, FILIPPO MARIA;SBARRA, CARLA;SEMPRINI CESARI, NICOLA;SPIGHI, ROBERTO;VALENTINETTI, SARA;VILLA, MAURO;ZOCCOLI, ANTONIO;C. Avanzini;
2010

Abstract

In September 2008 the Slim5 collaboration submitted a low material budget silicon demonstrator to test with protons at the PS beam at CERN. The beam test setup was composed of a four double sided microstrip reference telescope and different detectors (DUTs) placed inside: a 4k-Pixel Matrix of Deep N Well MAPS, developed in a 130 nm CMOS Technology and a high resistivity double sided silicon detector, with short strips at 45ring operator angle to the detectors edge, read out by the FSSR2 chip. All the systems were self-triggered and read out by a fast DAQ system. The beam test setup as the data acquisition and the trigger system are explained and the data acquisition performances are shown.
2010
L. Fabbri, M. Bruschi, R. Di Sipio, B. Giacobbe, A. Gabrielli, F. Giorgi, et al. (2010). The high rate data acquisition system for the SLIM5 beam test. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 617, 321-323 [10.1016/j.nima.2009.10.045].
L. Fabbri; M. Bruschi; R. Di Sipio; B. Giacobbe; A. Gabrielli; F. Giorgi; G. Pellegrini; C. Sbarra; N. Semprini; R. Spighi; S. Valentinetti; M. Villa;...espandi
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/80422
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact