Benzene is a widespread pollutant whose main source in the environment is automotive emission. There is increasing interest in the exposure of the population to this pollutant as benzene is present also in the indoor environment due to cigarette smoke, drinking water, and food. The aim of this study was to evaluate, in an adult nonsmoking population not occupationally exposed to benzene, whether it is possible to detect differences in the urinary concentration of trans,trans-muconic acid (t,t-MA) between low and high environmental exposure to benzene. A study sample of 31 employees working in pharmacies in a large town in Italy with low environmental exposure to benzene (4.8 microg/m3) was compared to a high (8.1 microg/m3) benzene exposure group. Analysis of urinary t,t-MA was carried out by high-performance liquid chromatography (HPLC; photodiode array detector); analysis of environmental benzene samples was by gas chromatography/mass spectroscopy (GC-MS). The statistical analysis revealed no significant differences in urinary levels of t,t-MA of subjects with high (mean concentration: 157.9 microg/g creatinine) versus low exposure (mean concentration: 114.2 microg/g creatinine). Data show that it is difficult to correlate urinary t,t-MA with benzene exposure at parts per billion levels.

SANGUINETTI G., ACCORSI A., BARBIERI A, RAFFI GB, VIOLANTE FS (2001). Failure of urinary trans,trans muconic acid as a biomarker for indoor environmental benzene exposure at ppb levels. JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH. PART A, 63(8), 599-604.

Failure of urinary trans,trans muconic acid as a biomarker for indoor environmental benzene exposure at ppb levels

VIOLANTE FS
Ultimo
2001

Abstract

Benzene is a widespread pollutant whose main source in the environment is automotive emission. There is increasing interest in the exposure of the population to this pollutant as benzene is present also in the indoor environment due to cigarette smoke, drinking water, and food. The aim of this study was to evaluate, in an adult nonsmoking population not occupationally exposed to benzene, whether it is possible to detect differences in the urinary concentration of trans,trans-muconic acid (t,t-MA) between low and high environmental exposure to benzene. A study sample of 31 employees working in pharmacies in a large town in Italy with low environmental exposure to benzene (4.8 microg/m3) was compared to a high (8.1 microg/m3) benzene exposure group. Analysis of urinary t,t-MA was carried out by high-performance liquid chromatography (HPLC; photodiode array detector); analysis of environmental benzene samples was by gas chromatography/mass spectroscopy (GC-MS). The statistical analysis revealed no significant differences in urinary levels of t,t-MA of subjects with high (mean concentration: 157.9 microg/g creatinine) versus low exposure (mean concentration: 114.2 microg/g creatinine). Data show that it is difficult to correlate urinary t,t-MA with benzene exposure at parts per billion levels.
2001
SANGUINETTI G., ACCORSI A., BARBIERI A, RAFFI GB, VIOLANTE FS (2001). Failure of urinary trans,trans muconic acid as a biomarker for indoor environmental benzene exposure at ppb levels. JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH. PART A, 63(8), 599-604.
SANGUINETTI G.; ACCORSI A.; BARBIERI A; RAFFI GB; VIOLANTE FS
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/803284
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 12
social impact