This work describes a rapid and sensitive solid-phase microextraction (SPME) method for the isolation and analysis of methyl tert-butyl ether in water samples. Methyl tert-butyl ether was extracted from aqueous solutions using SPME fibre coated with Divinylbenzene/Carboxen/polydimethylsiloxane (30 microm film thickness) and analysed by GC-MS with a Hewlett Packard 6890/5973 system equipped with a capillary column coated with Vocol (30 m x 0.25 mm, 1.5 microm film thickness). Extraction parameters and chromatographic separation conditions were optimised. The developed method showed good analytical performance in terms of precision (RSD between 2% and 8%) and accuracy (mean recovery from 96% to 104%) with a detection limit of 14 ppt. Finally the method was applied to surface, tap and commercial mineral water samples, as well as snow samples collected along a busy road of Bologna town area. The median concentration of methyl tert-butyl ether in all these samples (0.05-0.4 ppb) was well below the maximum aqueous contamination levels in water adopted in the United States (13 ppb).

PIAZZA F., BARBIERI A., VIOLANTE FS, RODA A. (2001). A rapid and sensitive method for methyl tert-butyl ether analysis in water samples by use of solid phase microextraction and gas chromatography-mass spectrometry. CHEMOSPHERE, 44, 539-544.

A rapid and sensitive method for methyl tert-butyl ether analysis in water samples by use of solid phase microextraction and gas chromatography-mass spectrometry

VIOLANTE FS;
2001

Abstract

This work describes a rapid and sensitive solid-phase microextraction (SPME) method for the isolation and analysis of methyl tert-butyl ether in water samples. Methyl tert-butyl ether was extracted from aqueous solutions using SPME fibre coated with Divinylbenzene/Carboxen/polydimethylsiloxane (30 microm film thickness) and analysed by GC-MS with a Hewlett Packard 6890/5973 system equipped with a capillary column coated with Vocol (30 m x 0.25 mm, 1.5 microm film thickness). Extraction parameters and chromatographic separation conditions were optimised. The developed method showed good analytical performance in terms of precision (RSD between 2% and 8%) and accuracy (mean recovery from 96% to 104%) with a detection limit of 14 ppt. Finally the method was applied to surface, tap and commercial mineral water samples, as well as snow samples collected along a busy road of Bologna town area. The median concentration of methyl tert-butyl ether in all these samples (0.05-0.4 ppb) was well below the maximum aqueous contamination levels in water adopted in the United States (13 ppb).
2001
PIAZZA F., BARBIERI A., VIOLANTE FS, RODA A. (2001). A rapid and sensitive method for methyl tert-butyl ether analysis in water samples by use of solid phase microextraction and gas chromatography-mass spectrometry. CHEMOSPHERE, 44, 539-544.
PIAZZA F.; BARBIERI A.; VIOLANTE FS; RODA A.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/802039
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 49
  • ???jsp.display-item.citation.isi??? 42
social impact