Background: Stent placement in the distal duodenum or proximal jejunum with a therapeutic gastroscope can be difficult, because of the reach of the endoscope, loop formation in the stomach, and flexibility of the gastroscope. The use of a colonoscope may overcome these problems. Objective: To report our experience with distal duodenal stent placement in 16 patients using a colonoscope. Methods: Multicenter, retrospective series of patients with a malignant obstruction at the level of the distal duodenum and proximal jejunum and treated by stent placement using a colonoscope. Main outcome measurements are technical success, ability to eat, complications, and survival. Results: Stent placement was technically feasible in 93% (15/16) of patients. Food intake improved from a median gastric outlet obstruction scoring system (GOOSS) score of 1 (no oral intake) to 3 (soft solids) (p = 0.001). Severe complications were not observed. One patient had persistent obstructive symptoms presumably due to motility problems. Recurrent obstructive symptoms were caused by tissue/tumor ingrowth through the stent mesh [n = 6 (38%)] and stent occlusion by debris [n = 1 (6%)]. Reinterventions included additional stent placement [n = 5 (31%)], gastrojejunostomy [n = 2 (12%)], and endoscopic stent cleansing [n = 1 (6%)]. Median survival was 153 days. Conclusion: Duodenal stent placement can effectively and safely be performed using a colonoscope in patients with an obstruction at the level of the distal duodenum or proximal jejunum. A colonoscope has the advantage that it is long enough and offers good endoscopic stiffness, which avoids looping in the stomach.

Jeurnink S.M., Repici A., Luigiano C., Pagano N., Kuipers E.J., Siersema P.D. (2009). Use of a colonoscope for distal duodenal stent placement in patients with malignant obstruction. SURGICAL ENDOSCOPY, 23(3), 562-567 [10.1007/s00464-008-9880-5].

Use of a colonoscope for distal duodenal stent placement in patients with malignant obstruction

Pagano N.;
2009

Abstract

Background: Stent placement in the distal duodenum or proximal jejunum with a therapeutic gastroscope can be difficult, because of the reach of the endoscope, loop formation in the stomach, and flexibility of the gastroscope. The use of a colonoscope may overcome these problems. Objective: To report our experience with distal duodenal stent placement in 16 patients using a colonoscope. Methods: Multicenter, retrospective series of patients with a malignant obstruction at the level of the distal duodenum and proximal jejunum and treated by stent placement using a colonoscope. Main outcome measurements are technical success, ability to eat, complications, and survival. Results: Stent placement was technically feasible in 93% (15/16) of patients. Food intake improved from a median gastric outlet obstruction scoring system (GOOSS) score of 1 (no oral intake) to 3 (soft solids) (p = 0.001). Severe complications were not observed. One patient had persistent obstructive symptoms presumably due to motility problems. Recurrent obstructive symptoms were caused by tissue/tumor ingrowth through the stent mesh [n = 6 (38%)] and stent occlusion by debris [n = 1 (6%)]. Reinterventions included additional stent placement [n = 5 (31%)], gastrojejunostomy [n = 2 (12%)], and endoscopic stent cleansing [n = 1 (6%)]. Median survival was 153 days. Conclusion: Duodenal stent placement can effectively and safely be performed using a colonoscope in patients with an obstruction at the level of the distal duodenum or proximal jejunum. A colonoscope has the advantage that it is long enough and offers good endoscopic stiffness, which avoids looping in the stomach.
2009
Jeurnink S.M., Repici A., Luigiano C., Pagano N., Kuipers E.J., Siersema P.D. (2009). Use of a colonoscope for distal duodenal stent placement in patients with malignant obstruction. SURGICAL ENDOSCOPY, 23(3), 562-567 [10.1007/s00464-008-9880-5].
Jeurnink S.M.; Repici A.; Luigiano C.; Pagano N.; Kuipers E.J.; Siersema P.D.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/800762
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 23
  • ???jsp.display-item.citation.isi??? 19
social impact