A fast and sensitive high-performance liquid chromatographic method has been developed for the determination in human plasma of MHPG (3-methoxy-4-hydroxyphenylethylenglycol) and VMA (vanillyl mandelic acid), the main metabolites of epinephrine and norepinephrine. Analyses were carried out at 325 nm while exciting at 285 nm on a reversed-phase column (Atlantis C18, 150×4.6 mm I.D., 5 μm) using a mobile phase composed of 2% methanol and 98% aqueous citrate buffer at pH 3.0. A careful solid-phase extraction procedure, based on mixed-mode reversed phase - strong anion exchange Oasis cartridges (MAX, 30 mg, 1 mL), was developed for the pre-treatment of plasma samples. Extraction yields were satisfactory, always higher than 90%. Calibration curves were linear over the 0.2-40.0 ng/mL concentration range for MHPG and over the 0.5-40.0 ng/mL concentration range for VMA. The method was successfully applied to plasma samples of former drug users undergoing detoxification therapy and subjects “at risk” of developing drug addiction.

Fast analysis of catecholamine metabolites MHPG and VMA in human plasma by HPLC with fluorescence detection and a novel SPE procedure / L. Mercolini; G. Gerra; M. Consorti; L. Somaini; M.A. Raggi. - In: TALANTA. - ISSN 0039-9140. - STAMPA. - 78:(2009), pp. 150-155. [10.1016/j.talanta.2008.10.049]

Fast analysis of catecholamine metabolites MHPG and VMA in human plasma by HPLC with fluorescence detection and a novel SPE procedure

MERCOLINI, LAURA;RAGGI, MARIA AUGUSTA
2009

Abstract

A fast and sensitive high-performance liquid chromatographic method has been developed for the determination in human plasma of MHPG (3-methoxy-4-hydroxyphenylethylenglycol) and VMA (vanillyl mandelic acid), the main metabolites of epinephrine and norepinephrine. Analyses were carried out at 325 nm while exciting at 285 nm on a reversed-phase column (Atlantis C18, 150×4.6 mm I.D., 5 μm) using a mobile phase composed of 2% methanol and 98% aqueous citrate buffer at pH 3.0. A careful solid-phase extraction procedure, based on mixed-mode reversed phase - strong anion exchange Oasis cartridges (MAX, 30 mg, 1 mL), was developed for the pre-treatment of plasma samples. Extraction yields were satisfactory, always higher than 90%. Calibration curves were linear over the 0.2-40.0 ng/mL concentration range for MHPG and over the 0.5-40.0 ng/mL concentration range for VMA. The method was successfully applied to plasma samples of former drug users undergoing detoxification therapy and subjects “at risk” of developing drug addiction.
2009
Fast analysis of catecholamine metabolites MHPG and VMA in human plasma by HPLC with fluorescence detection and a novel SPE procedure / L. Mercolini; G. Gerra; M. Consorti; L. Somaini; M.A. Raggi. - In: TALANTA. - ISSN 0039-9140. - STAMPA. - 78:(2009), pp. 150-155. [10.1016/j.talanta.2008.10.049]
L. Mercolini; G. Gerra; M. Consorti; L. Somaini; M.A. Raggi
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/78774
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 30
  • ???jsp.display-item.citation.isi??? 28
social impact