This article demonstrates the use of guided elastic waves (GEW) for multiple-in and multiple-out (MIMO) data communication in the framework of a structural health monitoring (SHM) system. Therefore, miniaturized low-voltage communication nodes have been developed. They are arranged in a spatially distributed and permanently installed network. Wireless exchange of encoded information across a metallic plate and a stiffened carbon-fiber reinforced plastics (CFRP) structure is investigated. A combination of square-wave excitation sequences and frequency-division multiplexing (FDM) is explored for parallel communication with multiple nodes. Moreover, the impact of the excitation-sequence length on the reliability of information transmission is studied in view of future energy-aware application scenarios. The presented system achieves in both studied structures error-free transmission at a data rate of 0.17 kbps (per carrier frequency) with a power consumption of 224 mW.
Kexel, C., Testoni, N., Zonzini, F., Moll, J., Marchi, L.D. (2020). Low-Power MIMO Guided-Wave Communication. IEEE ACCESS, 8, 217425-217436 [10.1109/ACCESS.2020.3042440].
Low-Power MIMO Guided-Wave Communication
Testoni, Nicola;Zonzini, Federica;Marchi, Luca De
2020
Abstract
This article demonstrates the use of guided elastic waves (GEW) for multiple-in and multiple-out (MIMO) data communication in the framework of a structural health monitoring (SHM) system. Therefore, miniaturized low-voltage communication nodes have been developed. They are arranged in a spatially distributed and permanently installed network. Wireless exchange of encoded information across a metallic plate and a stiffened carbon-fiber reinforced plastics (CFRP) structure is investigated. A combination of square-wave excitation sequences and frequency-division multiplexing (FDM) is explored for parallel communication with multiple nodes. Moreover, the impact of the excitation-sequence length on the reliability of information transmission is studied in view of future energy-aware application scenarios. The presented system achieves in both studied structures error-free transmission at a data rate of 0.17 kbps (per carrier frequency) with a power consumption of 224 mW.File | Dimensione | Formato | |
---|---|---|---|
Access_Low_Power_MIMO.pdf
accesso aperto
Tipo:
Versione (PDF) editoriale
Licenza:
Creative commons
Dimensione
3.7 MB
Formato
Adobe PDF
|
3.7 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.