In Agadir, a water-scarce Moroccan region, municipal and industrial wastewater is tertiary-treated to be reused in golf courses. Wastewater reuse has been constrained by severe emitter clogging that caused technical and financial problems. This study aimed to perform an in-depth characterization of the treated wastewater in relation to its susceptibility to cause clogging, and to assess the capacity of an aeration post-treatment to reduce the clogging potential. The post-treatment consisted in injecting different airflows (0-33 L/h/Lreactor) into the treated wastewater. The structural, morphological and elemental composition of the clogging matter collected in the irrigation pipeline was characterized using Scanning Electron Microscopy, Scanning Transmission Electron Microscopy, X-ray Diffraction and X-ray Energy Dispersive Spectroscopy. The 15-day aeration post-treatment at 16.5 L/h/Lreactor presented the best cost-benefit ratio. Organic matter was totally degraded. Calcium was reduced by 9%, bicarbonates by 54%. The analysis of the deposits induced by the aeration post-treatment revealed a relevant decrease of the major constituents of the clogging deposits found in the irrigation pipeline. The results show the effectiveness of post-aeration in biodegrading residual organic matter and precipitating several salts, thus reducing the clogging potential.
Benlouali, H., Karmal, I., Cherif Harrouni, M., Ghanbaja, J., Frascari, D., Hamdani, M., et al. (2021). Characterization of clogging deposits in an irrigation pipeline and effect of post-aeration on clogging potential of tertiary-treated wastewater. WATER SCIENCE AND TECHNOLOGY, 83(2), 309-321 [10.2166/wst.2020.552].
Characterization of clogging deposits in an irrigation pipeline and effect of post-aeration on clogging potential of tertiary-treated wastewater
Frascari, DarioWriting – Review & Editing
;
2021
Abstract
In Agadir, a water-scarce Moroccan region, municipal and industrial wastewater is tertiary-treated to be reused in golf courses. Wastewater reuse has been constrained by severe emitter clogging that caused technical and financial problems. This study aimed to perform an in-depth characterization of the treated wastewater in relation to its susceptibility to cause clogging, and to assess the capacity of an aeration post-treatment to reduce the clogging potential. The post-treatment consisted in injecting different airflows (0-33 L/h/Lreactor) into the treated wastewater. The structural, morphological and elemental composition of the clogging matter collected in the irrigation pipeline was characterized using Scanning Electron Microscopy, Scanning Transmission Electron Microscopy, X-ray Diffraction and X-ray Energy Dispersive Spectroscopy. The 15-day aeration post-treatment at 16.5 L/h/Lreactor presented the best cost-benefit ratio. Organic matter was totally degraded. Calcium was reduced by 9%, bicarbonates by 54%. The analysis of the deposits induced by the aeration post-treatment revealed a relevant decrease of the major constituents of the clogging deposits found in the irrigation pipeline. The results show the effectiveness of post-aeration in biodegrading residual organic matter and precipitating several salts, thus reducing the clogging potential.File | Dimensione | Formato | |
---|---|---|---|
Benlouali-2021-Aeration treatment & clogging-WST.pdf
accesso aperto
Tipo:
Versione (PDF) editoriale
Licenza:
Creative commons
Dimensione
872.2 kB
Formato
Adobe PDF
|
872.2 kB | Adobe PDF | Visualizza/Apri |
Benlouali-2021-SupplMat.pdf
accesso aperto
Tipo:
File Supplementare
Licenza:
Creative commons
Dimensione
357.29 kB
Formato
Adobe PDF
|
357.29 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.